![Simu SIMUDRIVE SD510 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/simu/simudrive-sd510/simudrive-sd510_manual_1279423026.webp)
EN
26/28
ERROR MESSAGES
4
FACTORY RESET
3
Error description
Code
Dead
Man
Actions and consequences
Cover
Led
Display Mem. Alarm
No error
—
00
No
No
—
Permanent command
—
10
No
No
—
Opening command during closing phase
—
11
No
No
—
Stop \ Safety chain \ Emergency stop
—
12
12
No
—
Photocell 1 : Opening safety activated
Blinks
20
No
No
Yes
Stay in deadman in opening
Photocell 1 : Closing safety activated
Blinks
21
No
No
Yes
Stay in deadman in closing
Photocell 2 : Opening safety activated
Blinks
22
No
Non
Yes
Stay in deadman in opening
Photocell 2 : Closing safety activated
Blinks
23
No
Non
Yes
Stay in deadman in closing
8.2k safety edge : Opening safety activated
Blinks
24
No
Yes
Yes
Stay in deadman in opening
8.2k safety edge : Closing safety activated
Blinks
25
No
No
Yes
Stay in deadman in closing
OSE safety edge : opening safety activated
Blinks
26
No
Yes
Yes
Stay in deadman in opening
OSE Safety edge : closing safety activated
Blinks
27
No
No
Yes
Stay in deadman in closing
Pass door opened (input 8.2k)
—
28
No
Yes
No
Block all operating function
Self-Testing Photo Cell 1 Error
Blinks
30
30
Yes
Yes
Stay in deadman on the phase where
photocell is active until next self test
Self-Testing Photo Cell 2 Error
Blinks
31
31
Yes
Yes
Stay in deadman on the phase where
photocell is active until next self test
Air Pressure Safety Edge Diagnostic Error
Blinks
33
33
Yes
Yes
A new air pressure safety self-test is
realized during a deadman closing
Pass door failure (8.2k)
—
34
34
Yes
No
Block all operating function
Reset needed
Pre-closing area too long
Blinks
35
35
Yes
Yes
Reset or Power On
—
No
40
Yes
—
End limit not reached
—
41
41
Yes
—
Interlocking in progress
—
44
No
No
No
Buzzer
—
45
No
No
—
Locking system monitor error
—
46
46
No
—
Radio receiver : Memory is full
—
50
No
No
No
Radio receiver : Missing memory
—
51
No
No
No
Internal Control Error: Internal Board default.
—
60
60
Yes
No
Block all operating function
Change control unit
Counter Cycle Overflow
—
65
No
No
No
Change the control unit
SIMU SAS F-70103 GRAY hereby declares that the product covered by these instructions and used as intended according to these instructions, is in compliance
with the essential requirements of the applicable European Directives 2006/42/EC and 2014/30/EU. The full text of the EU declaration of conformity is available on
www.simu.com. Bruno Stragliatti, 01/2021.
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
Содержание SIMUDRIVE SD510
Страница 28: ...www simu com ...