background image

EN

2/28

•  Check that a differential switch with a 0.03 threshold is fitted just before the power supply mains.

•  Check that earthing is carried out correctly: connect all metal parts for closure (doors, etc.) and all system 

components provided with an earth terminal.

•  SIMU declines all responsibility with respect to the automation safety and correct operation when other 

manufacturer’s components are used.

•  Only use original parts for any maintenance or repair operation.
•  Do not modify the automation components, unless explicitly authorized by SIMU.
•  Instruct the product user about the control systems provided and the manual opening operation in case 

of emergency.

•  Do not allow people or children to stay in the automation operation area.
•  Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation 

activation.

•  The user must avoid any attempt to carry out work or repair on the automation system, and always request 

the assistance of qualified people.

•  Anything which is not expressly provided for in the present instructions is not allowed.

1.4 Safety instructions relating to use and maintenance
WARNING:

 Important safety instructions. It is important for the safety of people to follow these instructions. 

Save these instructions.

WARNING:

 The drive has to be disconnected from its power source during cleaning, maintenance and 

when replacing parts.

•  This system can be used by children aged from 8 years and above and people with reduced physical, 

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or 

instruction concerning use of the appliance in a safe way and understand the hazards involved. Children 

must not play with the appliance. Cleaning and user maintenance should not be made by children without 

supervision.

•  Do not allow children to play with fixed controls. Keep remote controls away from children.

•  Frequently examine the installation for imbalance and signs of wear or damage to cables and springs. Do 

not use if repair or adjustment is necessary.

•  Watch the motorised installation while it is moving and keep people away until the motorised installation 

is fully extended.

•  For drives powered by a very low voltage removable power supply, only the power supply provided with 

the drive must be used.

•  For drives fitted with a manual release, operating conditions are given in the drive instructions.

   • All wiring has do be done with power off.

 

• PCB protective cover has to be placed before powering on.

Содержание SIMUDRIVE SD510

Страница 1: ...t of children s reach Keep the instructions together with the technical brochure for future reference Thisproductwasexclusivelydesignedandmanufacturedfortheusespecifiedinthepresentdocumentation Any other use not specified in the documentation could damage the product and be dangerous SIMU declines all responsibility for any consequences resulting from improper use of the product or use which is di...

Страница 2: ...Important safety instructions It is important for the safety of people to follow these instructions Save these instructions WARNING The drive has to be disconnected from its power source during cleaning maintenance and when replacing parts This system can be used by children aged from 8 years and above and people with reduced physical sensory or mental capabilities or lack of experience and knowle...

Страница 3: ...nths Risk of crushing between the ground and the lower edge of the door during closing Risk of jamming between the case and the door Risk of jamming between guides and door Solution Photocells connection on not self tested input to check every 6 months Obstacle detection on the top with self tested photocells DESCRIPTION OF SIMUDRIVE SD510 CONTROL BOX 2 2 1 Reference DESIGNATION REF SIMUDRIVE SD51...

Страница 4: ...uration and buttons Navigator menu buttons F1 Slow blow fuse 0 8A high breaking capacity Transformer primary winding protection H B C High breaking Capacity 1500A mini F2 Slow blow fuse 0 8A 24 Vdc output protection AFF 1 Display shows the operating phase AFF 2 Display indicates errors if any otherwise indicates door position ...

Страница 5: ...trol input is activated Led 8 On if command 2 control input is activated Led 9 On if auxiliary control input is activated Led 10 Off if stop or emergency stop control input is activated Led 11 Off if photocell 1 control input is activated Led 12 Off if photocell 2 control input is activated 2 4 Description of external programming interface Red light error indicator or maintenance Blinks to indicat...

Страница 6: ...tor and safety brake wiring Three phases T9 MOTOR AND CONTROL BOX CONNECTION 3 1 2 3 4 5 6 7 8 9 10 11 12 B1 B7 U V W 1 2 3 4 Moteur Antichute 5 6 8 7 U V W moteur triphasé bleu U moteur triphasé gris V moteur triphasé rouge W terre jaune vert fin de course 1 violet fin de course 1 violet 2 1 fin de course 2 noir 3 fin de course 2 noir 4 sonde thermique beige 5 manœuvre de dépannage bleu 6 manœuvre de...

Страница 7: ...mits depending on motor installation same as wires 3 4 Connect an external stop button Otherwise use a shunt between 18 and 19 Motor won t work if STOP is not connected 1 2 3 4 5 6 7 8 9 10 11 12 B1 B7 U V W 1 2 3 4 Antichute 5 8 U V W moteur triphasé bleu U moteur triphasé gris V moteur triphasé rouge W terre jaune vert fin de course 1 violet fin de course 1 violet 2 1 fin de course 2 noir 3 fin ...

Страница 8: ...s The control box is now in dead man mode Set up end limits with up and down buttons Check end limit leds lighting KEY SWITCH CONNECTION 4 Check the rotation direction If the axis rotates in the opposite direction to the desired one Stop the movement immediately Turn off power Reverse 13 and 15 on terminal block B2 Switch on the system again and repeat the rotation direction check operation Descri...

Страница 9: ...e is an access to the road safety edge 2 sets of photocells in down position 2 sets of self tested photocells in up position flashing light if there is an access to the road 5 2 Photocell wiring 5 2 1 In the case of a shutter which cannot lift a person 2 sets of not self tested photocells in down position When photocells are not self tested they must be checked every 6 months Connections B4 25 RX1...

Страница 10: ...4 32 TX2 2 B4 32 RX2 2 B4 30 TX1 2 B4 30 RX1 2 B4 31 RX2 1 B4 32 TX2 2 B4 32 RX2 2 RX1 5 RX2 3 BLUE DARK BLUE BROWN GREEN GREEN DARK BLUE DARK BLUE DARK BLUE BLACK GREEN GREEN OUTPUT OUTPUT Description Reference Cell Master Pro Bitech 5115929 Connections B5 34 B4 29 B5 34 B4 31 B5 33 TX1 1 B5 33 TX2 1 B4 25 RX1 3 B4 26 RX1 5 B4 27 RX2 3 B4 28 RX2 5 B4 29 RX1 2 B4 30 TX1 2 B4 30 RX1 1 B4 31 RX2 2 B...

Страница 11: ...ngs are done replace the protective cover before powering on 6 1 Display The 2 digits on the left display the current phase The 2 digits on the right display The default if there is one The door position in other case OPERATING PHASE DISPLAY Waiting for a command AC Total internal opening complete opening phase with priority to inside panel OU Total external opening complete opening phase with pri...

Страница 12: ...face button wiring CM1 Move the door in main tained pressure mode until the downward end limit Open the door with 1 impulse the door goes to the upward end limit Note that pushing on any button will stop the door Close the door with 1 impulse the door goes to the downward end limit Note that pushing on any button will stop the door Safety edge configuration 01 Resistive 8 2kohms 02 Optical 03 Pneu...

Страница 13: ...EN 13 28 6 3 Button and display operation Changes have to be done when the curtain is closed Example to modify d1 parameter in 03 ...

Страница 14: ... change closed and opened position or learn new operation time Before starting self learning process the installation has to be finished door installed Current phase and error display The door opens until the upward end limit The door closes until the downward end limit ...

Страница 15: ...n Closing after photocell activation X OF No closing after photocell activation X X d4 Closing on timer end On Closing after end of the timer OF No closing after end of the timer X X X d5 With or without clock system On With clock system OF Without clock system X X X d6 Number of closing attempts 00 to 50 Closing attempts 03 00 03 d1 Operating mode is preprogrammed during 1st power up procedure It...

Страница 16: ...closing timer 00 00 second to 4 0 minutes 1 0 1 0 30 tA Re closing timer 01 00 second to 4H00 10 10 05 tU Warning timer before starting 02 00 second to10 seconds 03 03 03 SETTING TIME ta PROCEDURE Between 0 sec and 1 min press the button or to increase or decrease the timer by 1s Between 1 min and 10 min press the button or to increase or decrease the timer by 5s Between 10 min and 1 hour press th...

Страница 17: ...ge without 8 2k 03 Air pressure safety edge with 8 2k 04 Pass door function E4 8 2k safety edge function 01 Safety input on CLOSING with COMPLETE re opening X X X 02 Safety input on CLOSING with 2 SECONDS re opening E5 OSE safety edge function 00 Inactive Programmed during 1st installation procedure 01 Safety input on CLOSING with COMPLETE re opening 02 Safety input on CLOSING with 2 SECONDS re op...

Страница 18: ...ing before start closing only X 02 Warning before start opening and closing X X J6 Low power output 1 function 00 Alarm 01 Timer 02 Door position X 03 Self test output NC 04 Self test output NO 05 Automatic interlocking output 06 Buzzer output 07 Service point output 08 Service point output deadman operating 09 Opened door indication X X 10 Closed door indication 11 Function not used 12 Function n...

Страница 19: ...D1 02 Partial open command X 03 Traffic management external command 04 Input photocell blanking X 05 Automatic interlocking input d3 Closing on photocell activation On Closing after photocell activation X OF No closing after photocell activation X X d4 Closing on timer end On Closing after end of the timer OF No closing after end of the timer X X X d5 With or without clock system On With clock sys...

Страница 20: ...med during 1st installation procedure 01 8 2k safety edge only 02 Air pressure safety edge without 8 2k 03 Air pressure safety edge with 8 2k 04 Pass door function E4 8 2k safety edge function 01 Safety input on CLOSING with COMPLETE re opening without self test X X X 02 Safety input on CLOSING with 2 SECONDS re opening without self test 03 Safety input OPENING STOP CLOSING COMPLETE re opening 04 ...

Страница 21: ...d on start J5 Warning before starting 00 No warning before starting 01 Warning before start closing only X 02 Warning before start opening and closing X X J6 Low power output 1 function 00 Alarm 01 Timer 02 Door position X 03 Self test output NC 04 Self test output NO 05 Automatic interlocking output 06 Buzzer output 07 Service point output 08 Service point output deadman operating 09 Opened door ...

Страница 22: ...4 0 Min 1 0 1 0 30 tA Re closing timer 00 Sec to 4H00 1 0 10 05 tL Reverse on safety action timer 00 s to 1 5 s 0 2 0 2 0 2 tt Traffic light timer 00 s to 10 s 10 10 10 tU Warning timer before starting 00 Sec to 10 Sec 03 03 03 t1 Function not used t2 Function not used t3 Function not used t4 Function not used ...

Страница 23: ...9 P3 00 à 99 P4 00 à 99 P5 00 à 99 P6 00 à 99 P7 00 à 99 P8 00 à 99 P9 Oldest default 00 à 99 PE Erase the ten last defaults On Erase defaults OF Keep defaults EM Expert menu activation On Second level programming OF First level programming PP Password protection On Active protection code OF No password protection PC Password change On Start changing password procedure OF No change Fr Factory rese...

Страница 24: ...and and thousand for the next service point value nx xx Displays hundred ten and units for the next service point value The number of cycles of the next maintenance mn Number total of cycles Cc Service point adjustment value Uu This function can be associated with a low power output parameters J6 J9 Jd configured in maintenance or maintenance deadman If the total number of cycles Cc exceeds the se...

Страница 25: ...ROR MESSAGES PE PASSWORD PROTECTION ACTIVATION PP The password protects the programming menu access Areset of the board is necessary for the protection to be active Example password activation1234 PASSWORD CHANGE PC 2 PASSWORD PROTECTION 2 ...

Страница 26: ... is active until next self test Self Testing Photo Cell 2 Error Blinks 31 31 Yes Yes Stay in deadman on the phase where photocell is active until next self test Air Pressure Safety Edge Diagnostic Error Blinks 33 33 Yes Yes A new air pressure safety self test is realized during a deadman closing Pass door failure 8 2k 34 34 Yes No Block all operating function Reset needed Pre closing area too long...

Страница 27: ... _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________________ _____________________________________________________________________________________________...

Страница 28: ...www simu com ...

Отзывы: