EN
12/28
6.2 First power up procedure
Motor rotation direction has to be checked and the end limits have to be set.
If ATEE error code appears, check end limit wiring (7-8-9), motor safety chain wiring (5-6), stop wiring (18/19) as well
as front face button wiring (CM1).
Move the door in main-
tained pressure mode until
the downward end limit.
Open the door with 1 impulse
the door goes to
the upward end limit.
Note that pushing on any button will stop the door.
Close the door with 1 impulse
the door goes to
the downward end limit.
Note that pushing on any button will stop the door.
Safety edge configuration
01
: Resistive 8.2kohms
02
: Optical
03
: Pneumatic
For mixed mode,
validate directly.
Содержание SIMUDRIVE SD510