![Simu SIMUDRIVE SD510 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/simu/simudrive-sd510/simudrive-sd510_manual_1279423009.webp)
EN
9/28
SAFETY ACCESSORIES WIRING
5
Connections
B3
OPTICAL SAFETY EDGE
22
BROWN
23
GREEN
24
WHITE
5.1 Optical safety edge wiring
SIMU advices about safety.
KIND OF DOOR
OPERATIN
MODE
SHUTTER WHICH
CANNOT
LIFT A PERSON
SHUTTER WHICH
CAN
LIFT A PERSON
MAINTAINED PRESSURE
No accessories required.
No accessories required.
MIXED
No accessories required.
2 sets of self-tested photocells in up position.
IMPULSE/AUTOMATIC
• safety edge.
• 2 sets of photocells in down
position.
• flashing light if there is an
access to the road.
• safety edge.
• 2 sets of photocells in down position.
• 2 sets of self-tested photocells in up position.
• flashing light if there is an access to the road.
5.2 Photocell wiring
5.2.1 In the case of a shutter which cannot lift a person
2 sets of not self-tested photocells in down position.
When photocells are not self-tested, they must be checked every 6 months.
Connections
B4:25
RX1:3
B4:26
RX1:5
B4:27
RX2:3
B4:28
RX2:5
B4:29
TX1:1
B4:29
RX1:1
B4:30
TX1:2
B4:30
RX1:2
B4:31
RX2:1
B4:31
TX2:1
B4:32
TX2:2
B4:32
RX2:2
BLUE
BLUE
DARK
BLUE
BROWN
BROWN
GREEN
GREEN
DARK
BLUE
DARK
BLUE
DARK
BLUE
GREEN
GREEN
OUTPUT
OUTPUT
Description
Reference
Cell Master Pro Bitech
5115929
Содержание SIMUDRIVE SD510
Страница 28: ...www simu com ...