Connection of room thermostats with cooling operation
N
out-
timer
Slave
T
N
T
Master
in-timer
in-C/O
24 V
230 V
Secos
L
L
L1-7 N1-7
The energy-saving controller registers the cooling mode via the C/O IN input and can control the individual thermal circuits accordingly.
Auto-inverting
In the app you can set whether the room thermostat signal should be inverted. With "Auto-inverting", the room thermostat automatically
detects whether the system is in cooling mode and automatically carries out signal processing (prerequisite: c/o out of the energy-saving
controller is connected to the master room thermostat).
Non-inverting
With "Non-inverting" there is no connection between the c/o out and the room thermostat, or the room thermostat does not have a
corresponding remote station. In this case, the controller inverts the room thermostat signals when switching to cooling mode (signal from
cold source at c/o in).
Secos
- Simplex Energy Control System
Installation instructions
|
Operating instructions