User manual for Digital Indicator and cooperating software
Functions of keys in "Single channel" mode:
•
go to main menu (press and hold for approx. 2 seconds),
•
change channel number,
•
change results presentation mode.
6.2.2.
”Graph” mode
In this mode (Fig. 6.9) the display shows measurement results in the form of a graph,
numeric form and in the form of a vertical bar. Numeric values (displayed over the graph) and
vertical bar (displayed to the right of the graph) indicate the value corresponding to the result
of the current measurement, irrespective of the set time scale of the graph. The graphical
indicator (bar displayed to the right of the graph) always indicates the measurement result to
the allowable measurement range ratio (see description of "
Hi value
" "
Lo value
" parameters
in the "
Inputs settings
" menu).
Fig. 6.9. Unit in "
Graph
" result presentation mode
Exceeding the
allowable measurement range
(Fig. 6.10, 6.11) is announced on the bar in
the form of an arrow indicating the direction of exceeding the range. If the measurement result
for the given channel exceeds the
allowable measurement range
(Fig. 6.10, 6.11) instead of
the current numeric value (displayed in the upper right corner) the display shows a "
-Hi-
" or "
-
Lo-
" message (depending on the direction of exceeding, see description of "
Upper ext.
" and
"
Lower ext.
" parameters in the "
Inputs settings
" menu).
19
MENU
ESC
channel number
vertical axis (values)
nominal range
extended range
measure result
in graphical mode (graph)
horisontal axis (time)
time unit
bargraph
unit name
channel name
measure result
in numerical mode