Use the Ace-In-The-Hole Automatic Booster Pump to 
boost city water pressure. Plumbing connections are 
described in this manual.

General Information

•  Pump only clean water with your Ace-In-The-Hole 

Automatic Booster Pump. To avoid clogging the 
pump and damaging the shaft seal, do not pump 
water containing solids, foreign material, sand, silt, 
or abrasives.

•  If you are boosting the pressure from a well pump, 

be sure that the system check valves are tight. If the 
system pressure drops when the well pump is not 
running, the Automatic Booster Pump may start and 
cycle. Excessive or rapid cycling may damage the 
motor and will void the warranty.

•  Do not use pipe joint compound on pump ports; 

use only PTFE tape to seal the threads. Pipe joint 
compound will damage the controller materials.

 

NOTICE: The priming plug has an O-ring already 
installed and does not require sealing.

•  Tighten all the piping joints to the pump hand tight 

plus 1-1/2 turns (not more).

 

Overtightening may break the pump and will void 
the warranty.

•  Pipe and fittings to the pump should be at least 

nominal 1” diameter. Pipe or fittings less than 1” in 
diameter will reduce performance and may damage 
the pump through cavitation.

•  Make sure that there are no air leaks or air pockets 

in the suction pipe. An air leak in the suction pipe 
may draw air in, although no water leaks out. Air 
leaks and air pockets will prevent the pump from 
priming properly, and can substantially reduce 
its performance.

•  The pump mount should be level, solid, as near as 

possible to the water source, and protected against 
excess moisture and flooding.

•  Use the shortest possible run for piping and the 

smallest possible number of fittings. Long pipe runs 
and numerous fittings increase friction and reduce 
the flow of water.

•  Support the weight of the piping and pump.
•  Do not allow the pump, pressure controller, or any 

system components to freeze. Freezing will damage 
the pump and void the warranty.

•  Periodically inspect the pump, pressure controller, 

and system components.

NOTICE: Local code may require a pressure relief valve 
or pressure regulator.

 Risk of leaks and flooding . Do not use this 

pump with inlet pressure less than 10 psi (70 kPa) or 
greater than 50 psi (345 kPa).

1117 0993

Figure 1 – Do Not Run the Pump With Inlet Shut Off

 Pressure hazard and risk of explosion . This 

pump can develop high pressure when operated with the 
discharge shut off or obstructed. For safe operation, we 
recommend the following:
If not already in the plumbing system, install a pressure 
relief valve in the pump discharge line capable of passing 
the full pump flow at 100 psi (689 kPa). If local code 
requires installation of a pressure relief valve capable 
of handling the full pump flow at a pressure less than 
100 psi (689 kPa), follow the code requirements. Run the 
relief valve discharge to a floor drain or other drain that 
will give adequate runoff.

Installation

 Risk of flooding . Be sure that all plumbing and 

fittings are rated to withstand the system pressure which 
you expect the pump to generate.
1.  Decide what’s the best place to install the pump. 

Think about these things:
•  it must be near the main water supply line
•  the pump must be accessible
•  the power cord must reach a power outlet
•  the controller’s LED lights must be visible
•  ease of plumbing
•  space saving

 

NOTICE: Installation of a low pressure safety cutoff 
switch on the pump discharge is recommended (and 
may be required by your local code) to shut off the 
power in case of low discharge pressure (caused by 
broken pipe, etc.).

2.  Mount the pump on a solid base in the location you 

have decided on.

3.  Choose a time that will allow you to shut off 

the water to the household while you install the 
Automatic Booster Pump.

4.  Shutoff the main water supply valve to the household.
5.  Open any faucet to relieve water pressure in the 

plumbing. Once the water pressure is relieved, close 
the faucet.

Содержание 4075SS-01

Страница 1: ...67 Fran ais Pages 9 15 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 16 22 2019 253PB560 0...

Страница 2: ...oming water supply broken pipe etc 5 Never run the pump dry To do so can damage internal parts overheat pump which can cause burns to people handling or servicing pump and will void warranty 6 Risk of...

Страница 3: ...flow of water Support the weight of the piping and pump Do not allow the pump pressure controller or any system components to freeze Freezing will damage the pump and void the warranty Periodically in...

Страница 4: ...plumbing system install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capa...

Страница 5: ...verheat and cause burns to persons handling the pump It may also damage the impeller and may damage the seal causing leaking or flooding and will void the warranty Fill the pump with water before star...

Страница 6: ...at it does not touch the fan blades Pump starts but then does not stop when no water is being used Leak in the system creating flow Verify that there are no leaks in the system creating flow Confirm t...

Страница 7: ...ring pump body 1 79 Gasket pump body 1 380 Capacitor kit 47 Capacitor ZBR48580 1 391 Pump body kit with plugs kit a 1 Pump body ZBR48610 1 4 Screw 6 96 Plug 2 410 Electronic control kit 409 Electroni...

Страница 8: ...plications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contaminati...

Страница 9: ...6 Risque d incendie ou d explosion Pour emp cher tout risque d incendie ou d explosion ne pomper que de l eau avec cette pompe Ne pas pomper de liquides inflammables ni de produits chimiques Ne pas u...

Страница 10: ...ement ce qui diminue le d bit de la pompe Supporter le poids de la tuyauterie et de la pompe Ne pas permettre la pompe son servor gulateur ni aux composants de syst me de geler Le gel endommagera la p...

Страница 11: ...ll sur la conduite de refoulement au cas o la pression de refoulement de la pompe chuterait Les codes de la municipalit peuvent aussi exiger l utilisation d un tel disjoncteur de s curit 10 Une fois l...

Страница 12: ...ession fonctionnement automatique a t ad quatement install e amorc e que le tuyau d aspiration n est pas obstru et qu il est ouvert Brancher le cordon lectrique de la pompe dans la prise de courant Le...

Страница 13: ...mpe d marre mais ne s arr te pas lorsque de l eau n est pas utilis e Fuite dans le syst me ce qui cr e un d bit Confirmer qu il n y a aucune fuite du syst me ce qui cr e un d bit Confirmer lorsque la...

Страница 14: ...orps de la pompe 1 79 Joint d tanch it corps de la pompe 1 380 Trousse de condensateur 47 Condensateur ZBR48580 1 391 Trousse de corps de pompe avec prises trousse a 1 Corps de la pompe ZBR48610 1 4 V...

Страница 15: ...R une pompe d eaux d gout qui a t install e au d taillant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamina...

Страница 16: ...Riesgo de incendio o de explosi n Para evitar el riesgo de incendio y explosi n bombee agua solamente con esta bomba No bombee l quidos ni sustancias qu micas inflamables No use la bomba cerca de luce...

Страница 17: ...sorios Trayectos de tuber a largos y numerosos accesorios aumentan la fricci n y reducen el flujo del agua Apoye el peso de la tuber a y de la bomba No permita que la bomba el controlador de presi n n...

Страница 18: ...ulte la Figura 2 Instale una v lvula de desahogo de presi n en la l nea de descarga capaz de pasar el caudal total de la bomba a 100 psi 689 kPa Si esta disposici n est en conflicto con el c digo siga...

Страница 19: ...o inundaci n y anular la garant a Llene la bomba con agua antes de encenderla Verifique que la bomba autom tica de refuerzo se haya instalado y cebado debidamente Consulte la P gina 4 y que la tuber a...

Страница 20: ...e detiene cuando no se est usando agua Fuga en el sistema est creando flujo Verifique que no haya fugas en el sistema creando flujo Confirme que el sistema con la v lvula principal de suministro cerra...

Страница 21: ...aquetadura unidad de la bomba 1 380 Juego de capacitor 47 Capacitor ZBR48580 1 391 Juego de la unidad de la bomba con tapones kit a 1 Unidad de la bomba ZBR48610 1 4 Tornillo 6 96 Tap n 2 410 Juego de...

Страница 22: ...comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacal...

Страница 23: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 24: ......

Отзывы: