For parts or assistance, call Simer Customer Service at 1-800-468-7867
General Information • Installation
3
For parts or assistance, call Simer Customer Service at 1-800-468-7867
Use the Ace-In-The-Hole Automatic Booster Pump to
boost city water pressure. Plumbing connections are
described in this manual.
General Information
• Pump only clean water with your Ace-In-The-Hole
Automatic Booster Pump. To avoid clogging the
pump and damaging the shaft seal, do not pump
water containing solids, foreign material, sand, silt,
or abrasives.
• If you are boosting the pressure from a well pump,
be sure that the system check valves are tight. If the
system pressure drops when the well pump is not
running, the Automatic Booster Pump may start and
cycle. Excessive or rapid cycling may damage the
motor and will void the warranty.
• Do not use pipe joint compound on pump ports;
use only PTFE tape to seal the threads. Pipe joint
compound will damage the controller materials.
NOTICE: The priming plug has an O-ring already
installed and does not require sealing.
• Tighten all the piping joints to the pump hand tight
plus 1-1/2 turns (not more).
Overtightening may break the pump and will void
the warranty.
• Pipe and fittings to the pump should be at least
nominal 1” diameter. Pipe or fittings less than 1” in
diameter will reduce performance and may damage
the pump through cavitation.
• Make sure that there are no air leaks or air pockets
in the suction pipe. An air leak in the suction pipe
may draw air in, although no water leaks out. Air
leaks and air pockets will prevent the pump from
priming properly, and can substantially reduce
its performance.
• The pump mount should be level, solid, as near as
possible to the water source, and protected against
excess moisture and flooding.
• Use the shortest possible run for piping and the
smallest possible number of fittings. Long pipe runs
and numerous fittings increase friction and reduce
the flow of water.
• Support the weight of the piping and pump.
• Do not allow the pump, pressure controller, or any
system components to freeze. Freezing will damage
the pump and void the warranty.
• Periodically inspect the pump, pressure controller,
and system components.
NOTICE: Local code may require a pressure relief valve
or pressure regulator.
Risk of leaks and flooding . Do not use this
pump with inlet pressure less than 10 psi (70 kPa) or
greater than 50 psi (345 kPa).
1117 0993
Figure 1 – Do Not Run the Pump With Inlet Shut Off
Pressure hazard and risk of explosion . This
pump can develop high pressure when operated with the
discharge shut off or obstructed. For safe operation, we
recommend the following:
If not already in the plumbing system, install a pressure
relief valve in the pump discharge line capable of passing
the full pump flow at 100 psi (689 kPa). If local code
requires installation of a pressure relief valve capable
of handling the full pump flow at a pressure less than
100 psi (689 kPa), follow the code requirements. Run the
relief valve discharge to a floor drain or other drain that
will give adequate runoff.
Installation
Risk of flooding . Be sure that all plumbing and
fittings are rated to withstand the system pressure which
you expect the pump to generate.
1. Decide what’s the best place to install the pump.
Think about these things:
• it must be near the main water supply line
• the pump must be accessible
• the power cord must reach a power outlet
• the controller’s LED lights must be visible
• ease of plumbing
• space saving
NOTICE: Installation of a low pressure safety cutoff
switch on the pump discharge is recommended (and
may be required by your local code) to shut off the
power in case of low discharge pressure (caused by
broken pipe, etc.).
2. Mount the pump on a solid base in the location you
have decided on.
3. Choose a time that will allow you to shut off
the water to the household while you install the
Automatic Booster Pump.
4. Shutoff the main water supply valve to the household.
5. Open any faucet to relieve water pressure in the
plumbing. Once the water pressure is relieved, close
the faucet.