Electrical / Preparing to Start the Pump
8
PREPARING TO START THE PUMP
Burn hazard. Never run pump dry.
Running pump without water may cause pump to over-
heat, damaging seal and possibly causing burns to per-
sons handling pump. Fill pump with water before start-
ing.
Hazardous pressure. Risk of explosion.
Never run pump with discharge valve closed. To do so
can boil water inside pump, causing hazardous pressure
in unit, risk of explosion and possibly scalding persons
handling pump.
1. Remove the priming plug from the priming tee and fill
the pump. Fill all piping between the pump and the
well and make sure that all piping in the well is full. If
you have also installed a priming tee in the suction
piping, remove the plug from the tee and fill the suc-
tion piping. See Figure 7.
2. Replace all fill plugs.
3.
Power on!
Start the pump. If you don’t have water
after 2 or 3 minutes, stop the pump and remove the
fill plugs. Refill the pump and piping. You may have
to repeat this several times in order to get all the
trapped air out of the piping. A pump lifting water 25’
may take as long as 15 minutes to prime.
4. After the pump has built up pressure in the system and
shut off, check the pressure switch operation by open-
ing a faucet or two and running enough water out to
bleed off pressure until the pump starts. The pump
should start when pressure drops to 30 PSI and stop
when pressure reaches 50 PSI. Run the pump through
one or two complete cycles to verify correct opera-
tion. This will also help clean the system of dirt and
scale dislodged during installation.
Congratulations on a sucessful installation.
If you were unsuccessful, please refer to the
Troubleshooting section (Page 10).
Branch
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
Max.
Fuse
0 - 100
101 - 200
201 - 300
301 - 400
401 - 500
Motor Load
Rating
(0 - 30)
(31 - 61)
(62 - 91)
(92 - 122) (123 - 152)
Model
HP
Volts
Amp
Amp
AWG WIRE SIZE (mm
2
)
2805E-02
1/2
115
9.4
15
14(2)
10(5.5)
10(5.5)
6(14)
6(14)
2810E-02
3/4
115/230
12.4/6.2
20/15
12/14(3/2) 10/14(5.5/2) 8/14(8.4/2)
6/12(14/3)
6/12(14/3)
Wiring Chart – Recommended Wire and Fuse Sizes
Fill p
u
mp
and piping
thro
u
gh
priming tee.
Can fill do
w
npipe
separately thro
u
gh
priming tee.
Figure 7: Prime the Pump