2
1.3
GENERAL DATA
TABLE 4 - General Specification
SUPER 90
SUPER 102
Main burner injectors
No off
13
15
Dia
mm
1.3
1.3
Water capacity
l (gal)
2.1 (0.5)
2.6 (0.6)
Minimum water flow
C.H.
l/min (gal/min)
22.0 (5.0)
28.0 (6.2)
D.H.W.
l/min (gal/min)
2.1 (0.5)
2.1 (0.5)
D.H.W. flow rate
30°C
l/min (gal/min)
12.6 (2.8)
14.1 (3.1)
at a temp. rise of
35°C
l/min (gal/min)
10.8 (2.4)
12.1 (2.7)
Static head
Min.
bar (psi)
0.5 (7.3)
0.5 (7.3)
Max.
bar (psi)
3.0 (43.5)
3.0 (43.5)
D.H.W. pressure
Min.
bar (psi)
0.9 (13.0)
0.9 (13.0)
Max.
bar (psi)
7.0 (102)
7.0 (102)
Weight
Empty
kg (lb)
48 (106)
54 (120)
Max lift
kg (lb)
45 (99)
51 (113)
Total (full)
kg (lb)
50 (110)
56 (124)
Electrical supply
230 V - 50 Hz, Fused at 3 A
Internal fuses
Line: F 1.6 A - P.C.B.: T 100 mA
Max. power consumption
Watt
150
210
Max. gas consumpt. (G20)
C.H.
m
3
/h (ft
3
/h)
2.8 (99)
3.6 (120)
D.H.W.
m
3
/h (ft
3
/h)
3.1 (109)
3.6 (120)
Max. working temperature
°C (F)
85 (185)
85 (185)
Integral exp. vessel capacity
l (gal)
7 (1.5)
7 (1.5)
TABLE 3a - Nominal boiler ratings (2 minutes after lighting) for “SUPER 90”
MODE
OUTPUT
INPUT (G.C.V.)
BURNER PRESSURE
kW
Btu/h
kW
Btu/h
mbar
inwg
CENTRAL HEATING RANGE
9.7
33,000
13.8
47,000
1.9
0.8
10.6
36,000
14.8
50,400
2.2
0.9
12.3
42,000
16.8
57,300
3.1
1.2
14.1
48,000
18.9
64,500
4.1
1.6
15.8
54,000
20.9
71,300
5.1
2.0
17.6
60,000
22.9
78,100
6.3
2.5
19.3
66,000
24.8
84,700
7.5
3.0
21.1
72,000
26.7
91,100
8.7
3.5
23.4
80,000
29.3
100,000
10.4
4.1
DOMESTIC HOT WATER
Max.
26.4
90,000
32.6
111,200
12.9
5.2
Min.
8.8
30,000
12.5
42,800
1.5
0.6
TABLE 3b - Nominal boiler ratings (2 minutes after lighting) for “SUPER 102”
MODE
OUTPUT
INPUT (G.C.V.)
BURNER PRESSURE
kW
Btu/h
kW
Btu/h
mbar
inwg
CENTRAL HEATING RANGE
15.3
52,200
18.6
63,500
3.9
1.5
17.4
59,400
20.6
70,300
4.9
1.9
20.3
69,300
23.5
80,200
6.4
2.5
22.8
77,800
26.0
88,700
7.8
3.1
25.0
85,300
28.3
96,600
9.3
3.7
27.0
92,100
30.5
104,100
10.8
4.3
29.7
102,000
33.1
113,000
12.7
5.1
DOMESTIC HOT WATER
Max.
29.7
102,000
33.1
113,000
12.7
5.1
Min.
10.5
35,800
13.0
44,300
2.0
0.8