Before commencing any service operation, ISOLATE the
mains electrical supply, and TURN OFF the gas supply at the
main service cock. It is the law that any service work must
be carried out by a competent person such as British gas or
other Corgi registered personnel.

8.1

HEAT EXCHANGER

– Remove the fan as described in section 8.3.
– In the 

“SUPER 90” 

remove the anti-vibration spring on

the top of the collector hood (fig. 20 a).

– Lift the collector hood assembly, tilt forwards, and remo-

ve the hood.

– Isolate the C.H. flow and return valves.
– Drain the heat exchanger using the drain cock (fig. 2).
– Unscrew the two heat exchanger unions and the locking

nuts, then lift out the heat exchanger.

– Re-assemble in reverse order, ensuring that the pressure

sensing pipes and anti vibration spring are correctly re-
fitted (figs.  20 - 21 - 22). The fan polarity is not impor-
tant except the earth conductor (G/Y which is marked
on the appliance). Refill, and re-commission the system
as described in section 4.

8.2

COMBUSTION CHAMBER INSULATION

The design of this appliance is such that the rear and side
insulation should not require replacement unless mechani-
cally damaged. 
To replace the insulation front panel, proceed as follows:
– remove the combustion chamber front panel as descri-

bed in section 5.1;

– replace the front insulation panel and glue it into posi-

tion on the front panel using the glue supplied. Re-
assemble in reverse order.

Should the rear or side panels become damaged, replace
them as follows.
– remove the heat exchanger as described in section 8.1;
– remove the side insulation panels followed by the rear

panel;

– re-assemble in reverse order, refill, and recommission the

system as described in section 4.

8.3

FAN ASSEMBLY

– Remove the outer casing and the sealed chamber front

panel as described in section 5.1.

– Disconnect the electrical connections to the fan. Note

the position of the earth conductor.

– Pull off the two pressure sensing lines (fig. 20).
– Unscrew the four screws securing the fan mounting

plate.

– Drop and tilt the fan assembly forwards and remove in a

downwards direction.

– Unscrew the three screws retaining the fan on the fan

plate (fig. 20). Remove the fan assembly.

– Transfer the pressure sensing Venturi from the old fan to

the new one, ensuring that it is fitted in the correct
direction as shown in fig. 25.

– Transfer the fan outlet seal onto the new fan.
– Reassemble in reverse order. Ensure that the earth con-

nection is correctly refitted. Note that the polarity (Line

and Neutral) is immaterial. Ensure that the pressure sen-
sing leads are correctly connected - red dot to red dot
and plain to plain.

8.4

MAIN BURNER

– Remove the main burner by following section 5.1.
– Transfer the pilot assembly onto the new burner assem-

bly.

– Re-assemble in reverse order and check for gas sound-

ness.

8.5

PILOT BURNER ASSEMBLY AND ELECTRODE

– Remove the combustion chamber front panel as descri-

bed in section 5.1.

– Unscrew electrode. TO REPLACE ELECTRODE ONLY.

Replace electrode, and go to last step.

– Remove the old pilot burner and replace with the new

one. Check that the critical dimensions are as shown in
fig 26.

– Re-assemble in reverse order and check for gas sound-

ness.

8

REPLACEMENT OF PARTS

Fig. 25

Fig. 26

Содержание SUPER 102

Страница 1: ...Super Combination Boilers installation and servicing instructions...

Страница 2: ......

Страница 3: ...INSTALLING THE BOILER 3 1 UNPACKING THE BOILER 9 3 2 FIXING THE WALL MOUNTING BRACKET 3 3 HANGING THE BOILER 10 3 4 FLUE AND TERMINAL PREPARATION 3 5 FLUE AND TERMINAL INSTALLATION 11 3 6 WATER CONNEC...

Страница 4: ...TION 8 3 FAN ASSEMBLY 8 4 MAIN BURNER 8 5 PILOT BURNER ASSEMBLY AND ELECTRODE 8 6 GAS VALVE 26 8 7 PRESSURE SWITCH 8 8 LIMIT THERMOSTAT 8 9 OVERHEAT THERMOSTAT 27 8 10 THERMISTOR C H OR D H W 8 11 IGN...

Страница 5: ...on 90 model If the wall thickness is less than 0 5 m 19 in the appliance can be installed from inside the room without access to the external wall although a wall liner is required This is available...

Страница 6: ...l capacity l gal 7 1 5 7 1 5 TABLE 3a Nominal boiler ratings 2 minutes after lighting for SUPER 90 MODE OUTPUT INPUT G C V BURNER PRESSURE kW Btu h kW Btu h mbar inwg CENTRAL HEATING RANGE 9 7 33 000...

Страница 7: ...n mm in mm in STANDARD FLUE KIT 745 29 1 4 620 24 1 2 650 25 1 2 WITH ONE EXTENSION KIT 1 560 61 1 2 1 435 56 1 2 1 465 57 3 4 WITH TWO EXTENSION KITS 2 375 93 1 2 2 250 88 1 2 2 280 89 3 4 1 4 HYDRAU...

Страница 8: ...be touched by a person using the bath or shower Attention is drawn to the requirements of the current I E E Wiring Regulations and in Scotland the electrical provisions of the Building Regulations ap...

Страница 9: ...g when the appliance is running The gas supply line should be purged NOTE Before purging open all doors and win dows also extinguish any cigarettes pipes and any other naked lights The complete instal...

Страница 10: ...ed system must only be filled by a competent per son using one of the approved methods shown in fig 6 The system design should incorporate the connections appropriate to one of these methods e the fol...

Страница 11: ...irculation an extra expansion vessel is required 2 9 3 Pressure and temperature gauge Separate pressure temperature gauge are located on the appliance facia panel 2 9 4 Safety valve A safety valve set...

Страница 12: ...W circuit within the casing of the appliance section 3 6 2 For specific information relating to fittings eg Showers washing machines etc suitable for connection in the D H W circuit consult the Local...

Страница 13: ...tisfied These minimum clearances are essential to provide access for servicing and are included on the wall mounting templates Open the paper wall mounting templates If a rear flue is to be used disca...

Страница 14: ...wall thickness is less than 0 5 m 19 in the flue air duct may be fitted without access to the outside wall provi ding that the optional wall liner kit is used This consists of a steel pipe 0 5 m long...

Страница 15: ...ength to be cut which is the wall thick ness X the clearance Y plus 155 mm 6 3 18 in All installations Cut the air duct square to the mark and remove all burrs and sharp edges Refer to fig 12 Hold the...

Страница 16: ...ms a good seal against the outside wall Fit the rubber sealing ring into the swaged groove in the air duct as shown in fig 13 Ensure that it is the correct way around 3 5 3 Connecting the duct assembl...

Страница 17: ...und and extend the pipe toensure that any discharge from the safety valve is safely routed to a drain The discharge pipe should be a minimum of 15 mm copper and should avoid sharp corners or upward pi...

Страница 18: ...W burner pressure is factory set and should not require adjusting If the burner pressure is low check that the appliance has not begun to modulate this will occur if the D H W flow rate is low If mod...

Страница 19: ...wrate by turning the restrictor nut on the divertor valve until a D H W temperature rise of approx 35 C is achieved This corresponds to the flowrates shown in table 4 turn off the tap remove the press...

Страница 20: ...he panel fig 19 Unscrew the 5 screws securing the combustion chamber front panel and remove the panel taking care not to damage the insulation Unscrew the spark electrode and withdraw Unscrew the pilo...

Страница 21: ...rder Check for gas soundness before fitting the outer case Ensure that all seals are correctly fitted and that the pressure sensing lines are correctly fitted as shown in figs 21 and 22 Ensure that th...

Страница 22: ...less than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required...

Страница 23: ...er PCB F1 fuse OK Is driver PCB F2 fuse OK Remove connector No 26 to 29 Does the fan start Replace C H thermistor Has pressure switch operated Replace F2 fuse Replace F1 fuse Does the relay K2 Driver...

Страница 24: ...Has pressure smoke switch operated Replace F2 fuse Clean or replace filter at inlet of divertor valve Replace driver PCB Is fuse F1 on driver PCB OK Replace driver PCB Check sensing pipe connections a...

Страница 25: ...21 7 INTERNAL WIRING DIAGRAMS AND VIEWS 7 1 FUNCTIONAL FLOW WIRING DIAGRAM Fig 23 a...

Страница 26: ...22 7 2 ILLUSTRATED WIRING DIAGRAM Fig 23 b...

Страница 27: ...e gauge 7 Temperature gauge 8 Divertor valve 9 Circulating pump 10 Burner manifold screws 11 Frost thermostat 12 C H thermistor 13 Collector hood 14 Sealed chamber 15 Air flue elbow 16 Pressure switch...

Страница 28: ...ump 10 Burner manifold screws 11 Frost thermostat 12 C H thermistor 13 Collector hood 14 Sealed chamber 15 Air flue elbow 16 Pressure switch 17 Fan 18 Limit thermostat 19 Heat exchanger 20 Pilot assem...

Страница 29: ...he heat exchanger as described in section 8 1 remove the side insulation panels followed by the rear panel re assemble in reverse order refill and recommission the system as described in section 4 8 3...

Страница 30: ...eturns to that pre viously adjusted isolate the mains electricity supply and reconnect push on the two 24 V modulation leads polarity is immaterial Restore the mains supply The appliance will light on...

Страница 31: ...he outer casing as described in section 5 1 Remove the two screws TCB M4 x 10 2 fig 14 and pivot the control box downwards then remove the two self tap ping screws 1 fig 14 and remove the control box...

Страница 32: ...bracket and pipe out of the appliance through the top Transfer the bracket and pipe to the new expansion ves sel and re assemble in reverse order Re pressurise and re commission the system as descri...

Страница 33: ...test the operation of the new clock Set it to the desired settings 8 25 TIME CLOCK OVERRIDE SWITCH Follow the procedure described for the Summer Winter switch section 8 18 8 26 FROST THERMOSTAT The f...

Страница 34: ...X 8226341886 1 60134 01 12 379 086 Overheat thermostat FIRT STB 901 1 A61732 00 12 397 597 Overheat thermostat RANCO LM7 P5041 alternative 1 61732 00 13 397 590 Limit thermostat ELMWOOD 52455R L085134...

Страница 35: ......

Страница 36: ...d d u u c c t t s s u u k k l l t t d d Jubilee Works Middlecroft Road Staveley Chesterfield Derbyshire S 43 3XN Tel 01246 471950 Fax 01246 281822 For service enquiries and boiler faults contact our s...

Отзывы: