Powering the System On and Off
007-4857-002
55
oo1c01-L1>
* power down
(* indicates all)
From the L1 prompt, display the system configuration information by entering the following
command:
001c01-L1>
config
:0 001c01 L0C
:2 002r01 L1H
:4 002r05 L3H
001c01-L1>
In L1 mode, you can obtain only limited information about the system configuration. An IRU has
information about its internal blades, and also when other IRUs are NUMAlink attached to the
IRU, information about those IRUs.
Note:
Verify that the power LED on the L1 display turns on and lights green and that your
controllers display that the system is powered on for each segment of the procedure, which
indicates that the power-on procedure is proceeding properly. If you have a problem while
powering on and an error message appears on the L1 controller, or the system console, see your
online log files and the information in “L1 Controller Error Messages” on page 145 to learn what
the error message indicates and how to best resolve the problem.