L1 Controller Error Messages
007-4857-002
145
L1 Controller
Error Messages
Table 7-2 lists error messages that the L1 controller generates and displays on the L1 display. This
display is located on the front of the IRU.
Note:
In Table 7-2, a voltage warning occurs when a supplied level of voltage is below or above
the nominal (normal) voltage by 10 percent. A voltage fault occurs when a supplied level is below
or above the nominal voltage by 20 percent.
Table 7-2
L1 Controller Messages
L1 System Controller Message
Message Meaning and Action Needed
Internal voltage messages:
ATTN: <
power VRM description
> high fault limit
reached @ x.xxV
30-second power-off sequence for the IRU.
ATTN: <
power VRM description
> low fault limit
reached @ x.xxV
30-second power-off sequence for the IRU.
ATTN: <
power VRM description
> high warning
limit reached @ x.xxV
A higher than nominal voltage condition is detected.
ATTN: <
power VRM description
> low warning
limit reached @ x.xxV
A lower than nominal voltage condition is detected.
ATTN: <
power VRM description
> level stabilized
@ x.xxV
A monitored voltage level has returned to within
acceptable limits.
Fan messages:
ATTN: FAN <fan description> fault limit reached @
xx RPM
A fan has reached its maximum RPM level. The
ambient temperature may be too high. Check to see
if a fan has failed.
ATTN: FAN <fan description> warning limit
reached @ xx RPM
A fan has increased its RPM level. Check the
ambient temperature. Check to see if the fan
stabilizes.
ATTN: FAN <fan description> stabilized @ xx
RPM
An increased fan RPM level has returned to normal.
Содержание SGI Altix 450
Страница 1: ...SGI Altix 450 System User s Guide Document Number 007 4857 002 ...
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 125: ...Altix 42U and 20U Rack Features 007 4857 002 103 Figure 5 1 Tall 42U Altix Rack and Front Lock ...
Страница 128: ......
Страница 139: ...Replacing IRU Components 007 4857 002 117 Figure 6 7 Replacing an IRU Fan B A Tighten screw ...
Страница 152: ...130 007 4857 002 6 Maintenance and Upgrade Procedures Figure 6 16 Extracting the Carrier Metal Filler Plate ...
Страница 164: ......
Страница 186: ......