L2 Operation
007-4857-002
95
To power on or power off a specific IRU, specify a current destination:
L2>
r 2 s 5 power up
L2>
To power on or power off all IRUs in a partition, enter the following:
L2> partition <
partition number
> <
power up
or
power down
>
To reset the system, enter the following:
L2>
reset
L2>
This command restarts the system by resetting all registers to their default settings and rebooting
the system controllers. Resetting a running system will cause the operating system to reboot and
all data in memory will be lost.
Console Mode from the L2
In console mode, all output from the system is visible and all input is directed to the system.
To enter console mode from L2, press
Ctrl+D
at the L2 prompt and observe the response:
L2>
Ctrl+D
entering system console mode (001c01 console0),
<CTRL_T> to escape to L2
.
<system output appears here>
.
To return to L2 mode from console mode, press
Ctrl+T
:
Ctrl+T
escaping to L2 system controller
L2>
At this point, you can enter any L2 or L1 command. When the command completes, the L2 returns
to console mode:
Re-entering system console mode (001c01 console0),
<CTRL_T> to escape to L2
To permanently engage the L2 mode, press
Ctrl+T
and then enter the
l2
command:
Содержание SGI Altix 450
Страница 1: ...SGI Altix 450 System User s Guide Document Number 007 4857 002 ...
Страница 4: ......
Страница 14: ......
Страница 16: ......
Страница 125: ...Altix 42U and 20U Rack Features 007 4857 002 103 Figure 5 1 Tall 42U Altix Rack and Front Lock ...
Страница 128: ......
Страница 139: ...Replacing IRU Components 007 4857 002 117 Figure 6 7 Replacing an IRU Fan B A Tighten screw ...
Страница 152: ...130 007 4857 002 6 Maintenance and Upgrade Procedures Figure 6 16 Extracting the Carrier Metal Filler Plate ...
Страница 164: ......
Страница 186: ......