AG02
Commissioning English
AG02 · Date
31.10.2012 · Art.
No.
82270 · Mod.
status
354/12
49
Output signals/ Wave form
Fig. 11: Tolerance range of the output channels
Fig. 12: Wave form
1
A before B; sense of rotation e
5.2 Motor control PWM
Setting the trim potentiometer
`
Due to the type of protection, only the covers
1
may be loosened (see
).
`
With the cover
1
iloosened, the drive's type of protection is no lon-
ger ensured.
`
Set the parameters on the trim potentiometers using a 2 mm slot
screwdriver.
`
When remounting the covers
1
take care that the seal are seated cor-
rectly!
The PWM motor control unit enables easy control of AG02. The use with dif-
ferent positioning controls is possible depending on the design.
Digital design: 2 digital inputs "Direction" & "Fast/Creep"
WARNING