AG02
Commissioning English
AG02 · Date
31.10.2012 · Art.
No.
82270 · Mod.
status
354/12
47
4.6 Earthing connection (PE, only ABM)
For protection against interference, the screens of the signal lines and the
power line must be connected on both sides. Potential differences cause
inadmissible currents on the screen. Apply the PE connection
1
to the
protective conductor potential below the connecting plugs (see
).
Use 6,3 mm flat connectors with short strands 2,5 mm² … 4 mm² (not in
the scope of delivery). For multiple actuators we recommend connecting
the earthing to a ground bar
1
(see
Fig. 10: Ground bar
5 Commissioning
Latch-up effects
Output stage of the driver is damaged.
`
The operating voltage of the device must be switched on together with
the downstream electronics unit (e. g. control).
Please carefully read the information on the actuator's mechanical and
electrical connection. This will ensure a trouble free commissioning and
operation.
Before operation, please check again:
•
that the supply voltage's polarity is correct.
•
correct connection of cable and signal lines.
•
secure actuator fixation on the hollow shaft.
•
correct mounting and functioning of the limit switches.
WARNING