Signamax
065-1163 F series RS-232/422/485 to 100BaseFX Media Converter
Configuration
19
Under the Serial Port Configuration heading, the field
Operation Mode
is a “read only” value indicating one of the
following modes: Console, RS -232, RS -422, or RS-485.
The mode is based on the DIP switches setting found on the
rear panel of the media converter.
Other fields that can be modified from this screen are:
communication data baud rate, parity, word length, stop bits
and flow control. Defaults for these are below:
• Baud rate – 38400
• Parity – N
• Word length – 8
• Stop bits - 1
• Flow control – none
Monitor Menu
This screen provides at-a-glance system status information.
TFTP Firmware Upgrade Menu
From this menu, the user can upgrade the existing firmware
to newer firmware available from a TFTP server. Simply
enter the file name of the updated firmware in the file name