![SignaMax 065 Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/signamax/065-series/065-series_user-manual_1268354017.webp)
Signamax
065-1163 F series RS-232/422/485 to 100BaseFX Media Converter
Introduction
12
Connection to Fiber Optic Cable
When connecting fiber cable to the 100BaseFX port of the
media converter, be sure the correct type – SC or ST -
connector is used. Follow the steps below to properly
connect the fiber cable:
1. Remove and keep the SC/ST port’s rubber cover. When
not connected to a fiber cable, the rubber cover should
be replaced to protect the optics.
2. Check that the fiber terminators are clean. You can clean
the cable plugs by wiping them gently with a clean tissue
or cotton ball moistened with a little ethanol. Dirty fiber
terminators on fiber optic cables will impair the quality of
the light transmitted through the cable and lead to
degraded performance on the port.
3. Connect one end of the cable to the SC/ST port on the
media converter and the other end to the SC/ST port on
the other device.
Note:
When inserting the cable, be sure the tab
on the plug clicks into position to ensure
that it is properly seated.
4. Check the LNK/ACT LED on the front panel of the media
converter to be sure that the connection is valid. (See
LED Indicators in the next section).