065-1163 F series RS-232/422/485 to 100BaseFX Media Converter
Configuration
18
through a media converter, it is necessary to set up a
connection between the local and remote media converter.
The connection setup process involves the server waiting
for a connection service request sent by the client. During
this process, the default setting is AUTO mode wherein the
system will determine which end is the server and which
end is the client automatically.
NOTE:
The server and client can be designated manually if necessary.
WARNING:
Changes to the settings are saved to a system flash
memory and do NOT take effect until a system reset or
reboot has occurred to validate the new settings.
From this screen, specify the IP address of the remote
media converter to which the connection is being made.
(The TCP port number is a number from 1024 to 65535).
NOTE:
Local and remote media converters must have the same TCP port
number in order for a connection to occur.
The Connection Idle Time field becomes active when there
is no traffic passing through the media converter. Set the
idle time value between 30 and 3600 seconds and when
this time has been reached, the connection will be
terminated automatically.