TECHNICAL DESCRIPTION AND OPERATING MANUAL ST131 <PIRANHA II> and ST131N
62
Frequency range 3, MHz
30-3000
Displayed noise level
FULL RANGE, dBm
Minus 90 (minus 100 for PC software)
1 KHz bandwidth, dBm
Minus 115
Maximum input level, dBm
5
Analysis speed, not less, GHz/sec
10
Values of bandwidth, MHz
2048, 1024, 512, 200, 100, 50, 20, 10, 5, 2,
1, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005,
0.002, 0.001 and 0.0005
Input attenuation value, dB
0 - 30 with step 5
Maximum allowed input voltage, V
380
“OPTICAL” CHANNEL
Threshold sensitivity, dBm
Minus 70
Dynamic range, not worse, dB
60
Frequency range, MHz
0.01-30
Spectral range, nm
770 – 1600 (550-1100)
Field of view, degree
30
“ACOUSTO-ELECTRIC” CHANNEL
Frequency range, KHz
0.01-125
Displayed noise level
FULL RANGE, dBm
Minus 110 (minus 140 for PC software)
1 KHz bandwidth, dBm
Minus 125
Input signal maximum level, dBm
Minus 5
Input amplifier gain, dB
6, 14, 20, 26, 34, and 40
Magnetic antenna ST131.MF
Frequency range (for passband ripple 4dB), Hz
30-30000
Conversion factor, at 1000 Hz, V*m/A
1.00±0.01
Threshold sensitivity, at 1000 Hz, not worse,
A/m*Hz
1/2
2*10
-6
NON-LINEAR JUNCTION DETECTOR
Frequency of test signal, KHz
150-220
MAIN UNIT
Dimensions, mm
190 x 97 x 50
Weight (without batteries), kg
0.8
Indication
TFT, 3.5’’, 240x320, 262144 colors
Interface
USB 2.0, up to 224 Mbit/s
Supply current, A
0.4-0.6
Power supply
6 AA type batteries (or rechargeable
batteries)