Modem Status, Customization, and Reset Commands
Rev.
6
Oct.18
Proprietary and Confidential - Contents subject to change
95
!POWERWAKE
continued
Configure ULPS (ULPM/PSM) wakeup sources (continued)
<active_time> (Requested active timer duration, in seconds)
•
0–4294967—Active timer duration. This timer is used only for PSM mode. The value
indicates the period during which the device remains reachable for mobile-terminated
(MT) transactions on transition from connected mode to idle mode.
•
If no value is specified, active time of 0 is configured.
<sync> (Synchronization method between on-board MCU and MDM in PSM/ULPM power
state transition)
•
1—MDM PMIC RTC alarm counts PSM time and wakes the MDM. The MCU keeps
the I2C module on to detect device power-up.
•
2—(Default) MDM PMIC RTC alarm counts PSM time and wakes the MDM. MCU
turns I2C module off until just before the <timeout> expires, then turns it on so device
power-up can be detected.
•
3—MDM completely powered off. MCU RTC alarm used to count PSM time and used
as wakeup source to exit PSM.
<gpio> (GPIO to configure as wakeup source)
•
36—GPIO36
•
38—GPIO38
•
39—GPIO39 (WPx5xx only. Does not apply to WP76xx/WP77xx.)
•
Multiple GPIOs can be configured as wakeup sources.
edge> (GPIO trigger type)
•
0—Off
•
1—High level trigger
•
2—Low level trigger
•
3—Rising edge trigger
•
4—Falling edge trigger
•
5—Both (rising or falling)
<adc> (ADC to configure as wakeup source)
•
2—ADC2
•
3—ADC3
•
Note: Only one ADC at a time can be configured as a wakeup source—If a different
<adc> is selected, the module clears the existing source before setting the new
source. For example, if ADC3 is currently configured and then ADC2 is configured, the
configuration for ADC3 is replaced by the ADC2 configuration.
<above> (ADC trigger lower bound, in mV)
•
0—Remove the ADC configuration
•
Valid range: 1–1800
<below> (ADC trigger upper bound, in mV)
•
0–1800
<interval> (ADC voltage sampling interval, in ms)
•
1–65535—Sampling interval
Table 3-2: Modem Status Command Details (Continued)
Command
Description