Appendix
23
UM_SUT50_EN.doc
Security Products
06.2014
11
Appendix
11.1 Technical data
Feature
Classification
Description
Data Interfaces
100Base-T Ethernet
100 Mbit/s (IEEE802.3)
Current-Loop-Interface (TTY)
20mA
RS232-Interface
RS485- Interface
Communications protocol
Network
UDP/IP, configurable IP-Address, Port 7000
Serial
SIMATRIX protocol (polling- und self-active mode),
SCU-Protocol 1 und 2
Mode of Operation
TTY-Slave
Polling-Mode – via TTY to Simatrix (2400 Bd)
TTY-Master
(Self-active mode) – to all SIMATRIX- Videomatrix-
Systems and -Servers via Current Loop (20mA,
2400 Bd), V24, or optionally RS485
LAN
Via UDP/IP to the SIMATRIX-Server or another
SUT50 in console router mode.
Baudrate of the Serial Interface
2400 to 19200* Baud/sec. adjustable
Baudrate depends on operation mode and system
configuration
Display components
Blue 5x8-Dotmatrix, 16 Digits,
alphanumerical
LCD-Display (STN-technology), white on blue
background.
LEDs to indicate operation mode and alert
Acoustical indicator
internal, linked with alert indication LED
Can be deleted seperately in case of an alarm
Control Elements
32 + 8 input- and control buttons
1 Shift button
Switching to second managing level
1 multifunctional analogue joystick
Camera angles (swing, tilt) and zoom / focus
adjustment
Configuration
Configuration menu, operated with buttons and
joystick. Display if menu items on the HMI device.
Alternative: Configuration via LAN with the configu-
ration tool VMnetCfg.exe possible.
Power Supply
DC 10-17 V, unregulated
Power supply from Videomatrix possible
Power over Ethernet (IEEE 802.3af)
Current Consumption
max. 200 mA
12V
Measures: (B x H
front
/H
back
x T) mm
Approx. 370 x 24/40 x 172