Controller
Type
Lamp Supply Wiring Location
Controller
Connector
Part Number
Microsense
MPC Midi
Case/
Puffin
Variant
The Pink Wire can
be connected to
the “B/D L”
terminal on the
controller
backplane, with the
black attached to
one of the “Lamp
Returns” to the left.
Microsense
MTC
OMU Lamp Supply (At the back of the cabinet to the
right of the MDU, amoungst the LV terminations)
none
Microsense
Sentinel
Dim/ Bright Sense is available at the back of the
controller cabinet in the LV Terminations section.
none
Telent
Optima
Dim/ Bright Sense is available at the back of the
controller cabinet in the LV Terminations section.
none
Peek TLC2 The Bright/Dim supply is available at "Lamp1" and
"Lamp2" terminals on the inner left hand side
termination panel.
Neutral is available at the regulatory sign neutral on the
lower terminal strip at the base ofthe cabinet.
none
Peek TSC3
The Bright/Dim supply is available at “Phase1",
"Phase2" and “N” terminals underneath the main
cabinet isolator.
none
Peek TSP
Lamp supply voltager available on single pin connector
adjacent to C63
Peek TSP Mod Kit
81-669
Peek TRX
LSM Module Pin 2 can be used for the Lamp supply
Reference
Peek
PTC-1
The Bright/Dim supply is available at “LVS1” or "LVS2",
only one of these lamp supplies can be monitored so
it’s recommended to monitor the 240V Supply on a
multi supply installation.
Terminal for
Pink Lamp
supply sense