The other boards in the system are powered over the RJ45 GSPI cables.
It is important that only supplied RJ45 cables are used as the cable must
carry all of the supply current. (Certain cheaper RJ45 cables are known to
have very thin conductors which will cause a problem if used on a Stratos
Outstation).
5.6
Controller Serial
Connection
The Stratos Outstation can be connected to the TR 2523 port of a traffic controller using
the correct RS232 interface cable and baud rate as shown in the tables below:
Supplier
Controller
RS232 Baud Rate
RS232 Cables (see
)
Siemens
ST950
19200
Standard
ST800
19200
Standard
ST900
19200
Standard
ST750
19200
Standard
ST700
19200
Standard
T400
1200
Standard
T500
1200
Standard
Microsense /
Telent
MPC
1200
St Extension
MTC
1200
St Extension
Sentinel
1200
Standard
Optima
1200
Loopback
Peek
TSC3
1200 (19200*)
Loopback
TRX
9600 (19200*)
Loopback
PTC-1
9600 (19200*)
Loopback
TSP
1200 (19200*)
Loopback
Motus
TM150
115200
Loopback
TM150
2P 115200
Loopback
* This baud rate can be set by the BDR handset command.
Table 24 – Controller RS232 Baud Rates and Cable Variants
RS232
Cable
Description
Part Number
Standard
This is a 1.6 metre cable for controllers which drive
hardware flow control signals DTR & RTS. The cable
terminates in 25-way D-type plug.
This cable is supplied as standard with the outstation.
667/1/47176/100