Controller
Type
Lamp Supply Wiring Location
Controller
Connector
Part Number
ST800
ST900
ST950
MDU:
L PL2 8z, 6d
N
PL2
20z,
24z,
28z
N PL2
22d,
26d,
30d
Use ¼" spade
crimps
Neutral may need
to come from
controller back
panel
ST750ELV Backplane: -48V PL12 Pin 4
0V
PL12
Pin
3
Use Dedicated Kit
667/1/47178/000
ST900ELV
ST950ELV
HPU:
-48V PL8 Pin 2 (Marked -)
0V PL8
Pin
1
(Marked
+)
531/4/03187/000
Siemens
T500
The pink wire can be connected to TBB2 on the MPM
(Main Processor Module) and the black to TBB1
none
Siemens
T400
Connect to the lamp supply “Hedgehog” using a spade
connector
Use ¼" spade
crimps
Microsense
MPC
Pelican
Variant
This requires this
connection for the
pink wire to be
soldered directly
onto the
backplane.
The black wire can
be attached to any
of the Lamp
Return Neutrals.
Note: There is
another similar
backplane that
uses ribbon
connections
instead of
terminals (for Midi
Cabinets), this has
the same solder
point available for
Lamp supply
connection.
Solder
point for
Lamp
Supply
Pink