Commands
SIWAREX FTA
6-131
Code Command explanation
Executable
in following
operating
states
73
Delete trace in MMC
The recorded data (trace function) stored in the
Micro Memory Card are deleted.
All
74
Delete trace in RAM
The stored data (trace function) in the RAM
memory are deleted.
All
75
Format MMC
The Micro Memory Card parameters are defined
corresponding with the definitions in the module data.
All of the stored content in the MMC is deleted.
Service
operation
76
Delete all MMC data (log data, measurement
data, …)
The data stored in the Micro Memory Card are
deleted.
Service
operation
77
Trace Single recording
The instruction causes a single recording of a trace
element. The time intervals between two trace
recordings do not require a fixed definition. With a
trace to MMC, renewed trace instructions will only
lead to a new trace recording after 50 ms. With
tracing to RAM, the recording is executed within
max. 10 ms.
Scale commands
100
Start weighing with tare zero setting mode
Start weighing with previous zero setting or taring
corresponding with the setting for tare / zero setting
mode.
No weighing
cycle, No
service
101
Start weighing without tare zero setting mode
Start weighing without zero setting or taring. This is
only permitted in non-calibratable operation
(country code not “OIML”).
No weighing
cycle, No
service
102
Start continuous weighing
Continuous start of sequential weighing cycles.
(Only possible in operating AWI mode)
No weighing
cycle, No
service
Содержание SIWAREX FTA