Messages and Diagnostics
SIWAREX FTA
7-144
Error
No.
Data and
command errors -
description
Solution
parameter
76
Value range
Adjustment digits
exceeded
The adjustment digits definition is too large. Enter a smaller
value. The highest permitted value is 16 777 215.
77
Regulation code not
permitted
The regulation code is incorrect. Enter the proper code.
Permitted is ---- or OIML.
.
78
Zero setting range
> 4% or zero setting
range exceeded
The zero definition range or zero setting range is too large. This
is the case if you have entered a zero setting range > 4% of the
maximum weighing range or > 20 % in the zero setting range in
DR 3 in calibratable operation (Specifications Code OIML in DR
3). The sum of negative and positive values always apply here.
Reduce the zero definition range or zero setting range.
79
Number of weight
ranges not allowed
The number of the weighing range is incorrect. Enter 1, 2 or 3.
80
Reserved
81
Relationship
between weighing
ranges implausible
The definitions for the weighing range (Max. and Numerical step)
are incorrect.
With a multi-segment scale, the min-value of the next higher
range must equal the max-value of the next lower range. The
max-value must be higher than the min-value.
With a multi-range scale, the min-value and max-value in
sequential ranges must always be greater and the max-value of
a range just always be greater than the min-value.
Check parameter definitions.
82
Numeral step not
plausible
At least one numeral step in DR 3 is incorrect.
The following numeral steps are permitted as numeral steps for
the three weighing ranges and the distribution value: 50, 20, 10,
5, 2, 1, .., 0.5, 0.2, 0.1, 0.05, 0.02, 0.01, 0.005, 0.002, 0.001,
0.0005, 0.0002, 0.0001.
In calibratable operation (Specifications Code OIML in DR 3) the
numeral step in all three weighing ranges may not be less than
one 6000th of the weighing range max-value.
In calibratable operation, the total numeral step (Specifications
Code OIML in DR 3) may not be less than the numeral step of
weighing range 1.
The numeral step of a weighing range may not be less than the
numeral step in the next lower lying weighing range.
Check the parameter.
83
Filter parameter
implausible
Filter parameter definitions in DR 3 not plausible.
Check the codes for the filter type (0..2) and the limit frequency
(0..9).
84
Characteristic value
not plausible
The characteristic value defined in DR 3 is incorrect. Set the
parameter to a valid value (1, 2 or 4).
85
Averaging filter
length not permitted
The mean value filter in DR 3 has incorrectly defined parameters.
Set the parameter for the depth of the mean value filter to
maximum 250.
86
Adjustment weight
error
The defined adjustment weights are incorrect. The weight values
must increase or be 0 if not used.
87
Reserved
88
Reserved
Содержание SIWAREX FTA
Страница 1: ...SIWAREX FTA Device Manual Status 05 2017 ...