To compensate the liquid column on the minus side, reset the zero point.
0D[LPXPOHYHO
8SSHUUDQJHYDOXH
/RZHUUDQJHYDOXH
&RQVWDQW
&RPSDULVRQ
OHYHO
/LTXLGILOOHG
QHJDWLYHSUHVVXUHOLQH
3UHVVXUHWUDQVPLWWHU
UHIHUHQFHOLQH
'
-
K
2
K
8
K
Y
Measurement assembly on a closed container (strong condensate
formation)
Formula:
Lower range value:
Δp
MA
= g · (h
U
· ρ - h
V
· ρ')
Upper range value:
Δp
MA
= g · (h
O
· ρ - h
V
· ρ')
h
U
Lower filling level
Δp
MA
Lower range value
h
O
Upper filling level
Δp
ME
Upper range value
h
V
Gland distance
ρ
Density of the measured medium in
the container
p
Pressure
ρ '
Density of fluid in the negative pres‐
sure line corresponds to the prevailing
temperature there
g
Acceleration due to gravity
The process connection on the negative side is a female thread
1
/
4
-18 NPT or an oval flange.
Lay the line for the negative pressure using a seamless steel tube 12 mm x 1.5 mm.
5.4
Installation with remote seal
Notes
● Keep the measuring system in the factory packing until it is installed in order to protect it from
mechanical damage.
● When removing from the factory packing and installing: ensure that damage to and
mechanical deformations in the membrane are prevented.
● Never loosen the sealed filling screws on the remote seal and the measuring instrument.
Installing/mounting
5.4 Installation with remote seal
SITRANS P320/P420 with 4 to 20 mA/HART
54
Operating Instructions, 11/2019, A5E44852162-AC
Содержание SITRANS P
Страница 10: ...Table of contents SITRANS P320 P420 with 4 to 20 mA HART 10 Operating Instructions 11 2019 A5E44852162 AC ...
Страница 272: ...Abbreviations SITRANS P320 P420 with 4 to 20 mA HART 272 Operating Instructions 11 2019 A5E44852162 AC ...
Страница 280: ...Index SITRANS P320 P420 with 4 to 20 mA HART 280 Operating Instructions 11 2019 A5E44852162 AC ...