B.1.4
Updating the Electronic Device Description (EDD)
Procedure
1. Check that the EDD revision match the Firmware revision in the device according to the
table in section Product compatibility (Page 16).
2. Go to the support page Software downloads (
processinstrumentation/downloads
3. Enter the product name in the field "Enter search term...".
4. Download the most current EDD of your device.
5. Save files to your computer in an easily accessed location.
6. Launch SIMATIC PDM – Device Integration Manager.
From the File menu, click "Read device descriptions from compressed source...".
7. Browse to the zipped EDD file, select and open it.
8. Use the "Integration" function to integrate the EDD into the device catalog. The EDD is now
accessible via SIMATIC Manager.