Safety notes
2.2 Installation in hazardous locations
FC410 with Modbus
Operating Instructions, 02/2016, A5E33120874-AC
19
If the equipment is placed in a "ta" environment (Zone 20), the maximum process
temperature shall be as follows:
Ta (°C)
Maximum Process Temperature per Temperature Class (°C)
60
-40
55
-10
50
20
45
50
40
80
35
110
30
140
Special conditions for safe use
In general, it is required that:
●
The equipment shall not be opened when energized and when an explosive gas or dust
atmosphere may be present..
●
Appropriate cable connectors are used.
●
Sensor is connected to the potential equalization throughout the hazardous area.
●
EN/IEC 60079-14 is considered for installation in hazardous areas.
Further information and instructions including approval-specific special conditions for safe
use in Ex applications can be found in the certificates on the accompanying literature CD
and at www.siemens.com/FC410 (
WARNING
Laying of cables
Explosion hazard
Cable for use in hazardous locations must satisfy the requirements for having a proof
voltage of at least 500 V AC applied between the conductor/ground, conductor/shield and
shield/ground.
Connect the devices that are operated in hazardous areas as per the stipulations applicable
in the country of operation.
WARNING
Field wiring installation
Ensure that the national requirements of the country in which the devices are installed are
met.
Содержание SITRANS FC410
Страница 2: ......
Страница 70: ...Commissioning 6 14 Process variables FC410 with Modbus 68 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 92: ...Troubleshooting FAQs 10 2 Troubleshooting FC410 with Modbus 90 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 142: ...Sensor dimension dependent default settings FC410 with Modbus 140 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 146: ...Zero point adjustment FC410 with Modbus 144 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 150: ...CRC calculation FC410 with Modbus 148 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 152: ...Exception codes E 1 Exception handling FC410 with Modbus 150 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 154: ...Float definition F 1 Float definition FC410 with Modbus 152 Operating Instructions 02 2016 A5E33120874 AC ...