Zero point adjustment
FC410 with Modbus
142
Operating Instructions, 02/2016, A5E33120874-AC
Zero point calculation
During zero point adjustment, an average value is automatically calculated using the
following formula:
Zero Point Offset Value
Average of N flow values
x
i
is an instantaneous flow value sampled in
the time domain
N = Number of samples during zero point
adjustment
The offset value must be within the determined Zero Point Offset Limit (Modbus address
2140).
Note
Exceeded zero point offset limit
If the offset value is greater than the configured limit, proceed as follows:
•
Check that the tube is completely filled and that the flowrate is absolute zero.
•
Check the validity of the configured zero point offset limit.
•
Repeat the zero point adjustment.
Zero point standard deviation
After completion of the procedure, the standard deviation is calculated in accordance with
the following formula:
Zero Point Standard Deviation
Standard deviation of N values
The standard deviation contains important feedback on the homogeneity of the fluid, for
example on the presence of bubbles or particles.
Содержание SITRANS FC410
Страница 2: ......
Страница 70: ...Commissioning 6 14 Process variables FC410 with Modbus 68 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 92: ...Troubleshooting FAQs 10 2 Troubleshooting FC410 with Modbus 90 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 142: ...Sensor dimension dependent default settings FC410 with Modbus 140 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 146: ...Zero point adjustment FC410 with Modbus 144 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 150: ...CRC calculation FC410 with Modbus 148 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 152: ...Exception codes E 1 Exception handling FC410 with Modbus 150 Operating Instructions 02 2016 A5E33120874 AC ...
Страница 154: ...Float definition F 1 Float definition FC410 with Modbus 152 Operating Instructions 02 2016 A5E33120874 AC ...