Parameter description
58
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.
9
Multi-step speed and PLC
Code
Description
Setting range
Default Modify
Modbus
Address
F9.33
Multi-step
freq.14
0.00 ~ Max
frequency
50.00 Hz
о
0A21H
F9.34
Multi-step
freq.15
0.00 ~ Max
frequency
50.00 Hz
о
0A22H
F9.35
PLC Multi-step
Freq.1
selection
0: Multi-step
digital setting
1: AI1
2: AI2
3: K
eypad
potentiometer
4:
Pulse input
0
о
0A23H
F9.36
PLC Multi-step
Freq.7
selection
0
о
0A24H
6.A Wobble frequency running group
Code
Description
Setting range
Default Modify
Modbus
Address
FA.00
Wobble
amplitude
0.0~50.0%
0.0%
о
0B00H
FA.01
Jitter frequency
0.0~50.0%(to FA.00)
0.0%
о
0B01H
FA.02
Jitter Time
5~50ms
5ms
о
0B02H
FA.03
Wobble freq. up
time
0.1~999.9s
5.0s
о
0B03H
FA.04
Wobble freq.
down time
0.1~999.9s
5.0s
о
0B04H
FA.05
Amplitude mode
0: Relative to the
central freq.
1: Relative to Max.
frequency
0
о
0B05H
Содержание SINAMICS V50