Parameter description
31
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.1 Start and stop control (F1)
Code
Description
Setting range
Default
Modify Modbus
Address
F1.13
Energy
consumption
brake
validity
0: Disabled
1: Enabled
0
0
020DH
F1.14
Energy
consumption
brake action
voltage
380V: 650~750V
220V: 360~390V
700V
380V
0
020EH
F1.15
Power failure
and fault
restart
0: Disable
1: Enabled for
power failure
2: Enabled for fault
3: Enabled for both
Note: Power
recovery restart is
only valid for
terminal 2-wires
mode. Fault restart
is invalid for under-
voltage fault.
0
0
020FH
F1.16
Waiting time
for restart
0.0~3600s
2.0s
0
0210H
F1.18
Rotational
speed
tracking
direction
inspection
0: Disable
1: Enable
0
0
0212H
F1.19
Rotational
speed
tracking
direction
inspection
time
10~1000ms
50ms
0
0213H
Содержание SINAMICS V50