Replacing a fan in the AM600
①
Fixing screws
②
Fan cover
③
Fan connector
Figure 9-4
Replacing a fan in the AM600
Removal steps
1. Open the fan cover using a suitable tool
①
(slotted screwdriver or Torx screwdriver).
2. Open the fan cover
②
.
3. Withdraw the fan connector
③
(cable).
4. Remove the fan cover together with the fan
②
from the fastening lugs.
Installation steps
1. Insert the new fan cover together with the fan
②
into the fastening lugs.
2. Insert the fan connector
③
.
3. Fold in the fan cover
②
and secure it with the captive screws provided.
Note
Checking the fastenings
● Attach the fan cover using a suitable slotted screwdriver or Torx screwdriver and check
that the connections are secure.
Tightening torque: 1.8 Nm (15.9 lbf in )
Service and maintenance
9.2 Replacing components
Manual, 06/2019, 6SL3097-5AW00-0BP1
163
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......