
0LQLPXPFXUYH
$
FF
HO
HU
DW
LR
Q
7UDYHUVLQJGLVWDQFH V>P@
D
>P
Vt
@
6,(0(16+\EULG&DEOH
Figure 8-4
Hybrid cable: acceleration as a function of the traversing path (minimum curve)
Table 8-5
Core assignment
Designation/
Color
Meaning
Signal name
Cross-section
[mm
2
(AWG)]
Load
[A]
YE/PK/GN/BU
DRIVE‑CLiQ signal cable (shielded) DRIVE-CLiQ
(1x4xAWG22)/C -
RD
Electronics power supply
P48
2.5 (AWG 12)
10
BU
Ground (GND)
M
2.5 (AWG 12)
10
DCP
DC link v
DCP
4 (AWG 10)
25
DCN
DC link voltage -
DCN
4 (AWG 10)
25
GN/YE
Protective conductor (PE)
PE
4 (AWG 10)
-
Derating characteristic
● If you use the cable at increased ambient temperatures (40 to 55 °C) you must reduce the
DC link current accordingly.
Control cabinet design
8.4 Connection system
136
Manual, 06/2019, 6SL3097-5AW00-0BP1
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......