4.3.3
X21 terminal strip for operating state
Table 4-2
Terminal strip X21 operating state
Terminal
Function
Technical data
1
RDY
Ready signal;
Output referred to 24 V electronics ground
Current carrying capacity: 100 mA (short-circuit proof)
Meaning:
The terminal has +24 V, if the electronics power supply is
in the specified range.
Brief voltage pulses of the 24 V supply outside of the
specified voltage range are displayed via the RDY signal
(not storing). The function of the drive train of the S120M
system is not affected by this.
If the supply voltage is permanently outside of the permit‐
ted range or if the supply voltage is exceeded by an im‐
permissible amount, the drive train of the S120M system is
shut down in a controlled way. The RDY signal displays
the fault during shutdown.
2
DC LINK
Notification: DC link voltage is present at the distributed
line
Output referred to 24 V electronics ground
Current-carrying capacity: 100 mA (short-circuit proof)
Meaning:
The terminal has 0 V, if the DC link voltage is > 50 V.
Note:
Hazardous DC link voltages may be present at any time
regardless of the state of the system.
3
TEMP
Alarm signal: AM600 overtemperature
Meaning:
Normally, 24 V is available at this terminal, and for an
overtemperature condition, 0 V.
4
M
Electronics ground
Maximum connectable cross-section: 1.5 mm
2
(AWG 16)
Type: Screw terminal 1 (see Chapter "Connectable conductor cross-sections for screw terminals" (Page 146))
Adapter Module 600
4.3 Interface description
Manual, 06/2019, 6SL3097-5AW00-0BP1
61
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......