Tightening torque:
● Initially, tighten the nuts by hand
● Then tighten with 6 Nm (53.1 lbf in)
in the specific sequence 1 to 4, diagonally
Note
Installation location in the cabinet
● Mount the Adapter Modules 600 vertically in the control cabinet.
4.7.2
Mounting an AM600 using spacing bolts
In order to increase the mounting depth of an AM600, use spacing bolts (Article number:
6SL3462-1CC00-0AA0). This means that you can directly combine the AM600 with SINAMICS
components in booksize format with internal air cooling.
Table 4-5
Number of spacing bolts and holes for the AM600
Module width in [mm] Number of spacing bolts
Number of holes/press-in nuts
75
4
4
Preparing the mounting panel
● Inserting M6 press-in nuts into the mounting panel
● Distance 25 mm ±0.15 mm for module width 75 mm
①
M6 press-in nuts
②
Mounting panel
Figure 4-6
Installing the M6 press-in nuts on the rear of the mounting panel
Adapter Module 600
4.7 Mounting
68
Manual, 06/2019, 6SL3097-5AW00-0BP1
Содержание Sinamics S120M
Страница 1: ...Equipment Manual Distributed drive technology Edition www siemens com drives 06 2019 S120M SINAMICS ...
Страница 2: ......
Страница 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 32: ...Fundamental safety instructions 2 4 Residual risks of power drive systems 30 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Страница 185: ......