![Siemens SINAMICS GM150 Скачать руководство пользователя страница 226](http://html.mh-extra.com/html/siemens/sinamics-gm150/sinamics-gm150_operating-and-installation-instructions_378206226.webp)
Installing the Power Stack Adapter
1. Execute the steps described in the section "Removing the Power Stack Adapter" in the
reverse order.
2. Tighten the fastening screws with a torque of 10 Nm.
3. Ensure the correct connection of the fiber-optic cables.
NOTICE
Faulty connection of fiber-optic cables
The faulty connection of the fiber-optic cables on the Power Stack Adapter can damage
the power semi-conductors.
Observe the connector assignment marked on the fiber-optic cables.
Maintenance
9.7 Repairs
SINAMICS GM150 6SL3815-2LN41-4AA2
226
Operating Instructions 04/2017