Fail-Safe Blocks
Fail-Safe Systems
8-30
A5E00085588-03
TIMEOUT Parameter
It can only safely be guaranteed that a signal level to be transferred will be
detected on the sender side and transferred to the recipient if it is present for at
least as long as the specified monitoring time (TIMEOUT).
The input TIMEOUT cannot be interconnected and must be assigned a constant
value. See "Monitoring Safety-Related Communication Between CPUs".
Error Handling
If a connection partner receives an invalid safety frame (e.g.: due to a check value
error (CRC) or watchdog error) or doesn’t receive a valid safety frame within the
TIMEOUT monitoring time, the outputs ERROR and SUBS_ON are set and the
substitute values are output. An error code is displayed at the output RETVAL.
Note
Once communication has been set up without errors, compliance with the assigned
monitoring time (TIMEOUT parameter) is checked.
Communication between the connection partners is reestablished. The data
received with valid safety frames is not applied to the outputs (= reintegrated) until
the input ACK_REI had a rising edge (e.g. via F_QUITES).
The block sets the output ACK_REQ to indicate that acknowledgment is required.
In the event of an error that is critical to safety, the system function SFC F_CTRL
is called. This records the event in the Diagnostic Buffer and requests a switch to
the reserve CPU if the error occurred only on the master CPU. For non-redundant
systems or a common-cause error occurring in both CPUs, the shutdown logic can
be configured to either disable the erred F-run-time group or the entire Safety
Program.
Error Information in Diagnostic Buffer
Error Code (W#16#...)
Description
75DAH
Error in the safety data format (error due to online modification
of the Safety Program or internal CPU fault)
Содержание SIMATIC S7 F
Страница 8: ...Important Information Fail Safe Systems viii A5E00085588 03 ...
Страница 16: ...Contents Fail Safe Systems xvi A5E00085588 03 ...
Страница 38: ...Product Overview Fail Safe Systems 1 22 A5E00085588 03 ...
Страница 56: ...Getting Started Fail Safe Systems 2 18 A5E00085588 03 ...
Страница 70: ...Safety Mechanisms Fail Safe Systems 3 14 A5E00085588 03 ...
Страница 115: ...Programming Fail Safe Systems A5E00085588 03 5 33 Examples Receive Block Send Block ...
Страница 154: ...Programming Fail Safe Systems 5 72 A5E00085588 03 ...
Страница 166: ...Operation and Maintenance Fail Safe Systems 6 6 A5E00085588 03 ...
Страница 332: ...Fail Safe Blocks Fail Safe Systems 8 144 A5E00085588 03 ...
Страница 344: ...References Fail Safe Systems B 2 A5E00085558 03 ...
Страница 350: ...Glossary Fail Safe Systems Glossary 6 A5E00085588 03 ...