4.9.3
Basic rules
It is often sufficient to follow a few elementary rules in order to ensure electromagnetic
compatiblity (EMC).
The following rules must be observed:
Shielding by enclosure
●
Protect the device against external interference by installing it in a cabinet or housing.
The housing or enclosure must be connected to the chassis ground.
●
Use metal plates to shield against electromagnetic fields generated by inductances.
●
Use metal connector housings to shield data conductors.
Wide-area ground connection
●
Plan a meshed grounding concept.
●
Bond all passive metal parts to chassis ground, ensuring large-area and low-HF-
impedance contact.
●
Establish a large-area connection between the passive metal parts and the central
grounding point.
●
Don't forget to include the shielding bus in the chassis ground system. That means the
actual shielding busbars must be connected to ground by large-area contact.
●
Aluminium parts are not suitable for ground connections.
Plan the cable installation
●
Break the cabling down into cable groups and install these separately.
●
Always route power cables, signal cables and HF cables through separated ducts or in
separate bundles.
●
Feed the cabling into the cabinet from one side only and, if possible, on one level only.
●
Route the signal cables as close as possible to chassis surfaces.
●
Twist the feed and return conductors of separately installed cables.
●
Routing HF cables:
avoid parallel routing of HF cables.
●
Do not route cables through the antenna field.
Shielding for the cables
●
Shield the data cables and connect the shield at both ends.
●
Shield the analog cables and connect the shield at one end, e.g. on the drive unit.
●
Always apply large-area connections between the cable shields and the shielding bus at
the cabinet inlet and make the contact with clamps.
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 486: ...Accessories 10 3 Reader and antenna holders SIMATIC RF600 486 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...