![Siemens SIMATIC RF640A Скачать руководство пользователя страница 241](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419241.webp)
Antennas
6.3 SIMATIC RF620A
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
241
6GT2812-1EA0x
Electrical data
Range
See section "Maximum read/write ranges of
Impedance
50 Ω
Polarization
Linear
VSWR (standing wave ratio)
≤ 2:1
Power
•
ETSI
•
≤ 2 W
•
FCC
•
≤ 1 W
Interfaces
Plug connection
30 cm coaxial cable with RP-TNC coupling
(for connection of the antenna cable)
Mechanical specifications
Material
PA 12
Color
Pastel turquoise
Tightening torque (at room temperature)
≤ 2 Nm
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 ... +70 °C
•
During transportation and storage
•
-40 ... +85 °C
Degree of protection
IP67
Shock resistant to EN 60068-2-27
50 g
2)
Vibrations according to EN 60068-2-6
20 g
2)
Design, dimensions and weight
Dimensions (H x W x D)
75 x 75 x 20 mm
Weight
100 g
Standards, specifications, approvals
Proof of suitability
•
ETSI
•
CE (ETSI EN 302208)
•
FCC
•
FCC (Title 47, Part 15.247), cULus
MTBF
1190 years
1)
The values differ for different dimensions/materials of the mounting surface.
2)
The values for shock and vibration are maximum values and must not be applied continuously.