329
6GT2812-2GB08
Electrical data
Range
See section "Maximum read/write ranges of
Impedance
50 Ω
Polarization
Linear, circular (can be switched over)
VSWR (standing wave ratio)
≤ 1.45
Power
≤ 2 W
Interfaces
Plug connection
RP-TNC coupling (for connection of the an-
tenna cable)
Mechanical specifications
Material
Pocan
Color
Pastel turquoise
Tightening torque (at room temperature)
≤ 2 Nm
Permitted ambient conditions
Ambient temperature
•
During operation
•
-25 ... +75 °C
•
During transportation and storage
•
-40 ... +85 °C
Degree of protection
IP65
Shock resistant to EN 60068-2-27
30 g
2)
Vibrations according to EN 60068-2-6
10 g
2)
Design, dimensions and weight
Dimensions (H x W x D)
198 x 198 x 60 mm
Weight
690 g
Status display
1 LED
Standards, specifications, approvals
Proof of suitability
CE (according to RED), FCC (Title 47, Part
15.247), cULus
MTBF
218 years
1)
The values differ for different dimensions/materials of the mounting surface.
2)
The values for shock and vibration are maximum values and must not be applied continuously.
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 486: ...Accessories 10 3 Reader and antenna holders SIMATIC RF600 486 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...