![Siemens SIMATIC RF640A Скачать руководство пользователя страница 113](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419113.webp)
Readers
5.2 SIMATIC RF615R
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
113
6GT2811-6CC10-xAA0
Typical transmission time per byte
•
Write access
•
2 ms
•
Read access
•
0.15 ms
Supply voltage
24 V DC (20 ... 30 V DC)
2)
Maximum permitted current consumption
0.3 A
Maximum permitted current consumption via
the digital I/O interface
0.5 A (< 20 °C; 0.33 A at 55 °C)
Current consumption (on standby), typical
•
20 V input voltage on the reader
•
200 mA / 4 W
•
24 V input voltage on the reader
•
170 mA / 4.1 W
•
30 V input voltage on the reader
•
150 mA / 4.2 W
Current consumption (at 400 mW transmit power), typical
•
20 V input voltage on the reader
•
260 mA / 5.2 W
•
24 V input voltage on the reader
•
220 mA / 5.3 W
•
30 V input voltage on the reader
•
170 mA / 5.1 W
Interfaces
Antenna connectors
1x RP-TNC
Power supply
1x RS422, M12 (8-pin)
Digital I/O interface
1x M12 (5-pin)
Digital inputs
1
Digital outputs
1
Ethernet interface
1x M12 (4-pin), 100 Mbps
Mechanical specifications
Material
Pocan (silicone-free)
Color
TI-Grey
Permitted ambient conditions
Ambient temperature
•
During operation
•
-25 ... +55 °C
•
During transportation and storage
•
-40 ... +85 °C
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...