![Siemens SIMATIC RF640A Скачать руководство пользователя страница 131](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419131.webp)
Readers
5.3 SIMATIC RF650R
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
131
5.3.3
Installation/mounting
Requirement
NOTICE
Close unused connectors
Note that the readers only have the specified degree of protection when all connectors are
in use or when unused connectors are closed with the protective caps.
CAUTION
Emitted radiation
The transmitter complies with the requirements of Health Canada and the FCC limit values
for subjecting persons to HF radiation, provided that a minimum spacing of 26 cm exists
between antenna and person. When the antennas are installed, you must therefore ensure
that a minimum spacing of 26 cm is maintained between personnel and antennas.
Mounting/installing the device
You can mount the reader in the following ways:
●
DIN rail T35 (S7-1200)
●
S7-300 standard rail
●
S7-1500 standard rail
●
directly on a flat surface using the VESA 100 mounting system (torque ≃ 1.5 Nm).
The positions of the mounting holes for the device are shown in the section Dimension
Содержание SIMATIC RF640A
Страница 12: ...Table of contents SIMATIC RF600 12 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 332: ...Antennas 6 8 SIMATIC RF680A SIMATIC RF600 332 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...
Страница 486: ...Accessories 10 3 Reader and antenna holders SIMATIC RF600 486 System Manual 11 2018 J31069 D0171 U001 A21 7618 ...