![Siemens SIMATIC RF640A Скачать руководство пользователя страница 413](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419413.webp)
Transponder
7.12 SIMATIC RF640T
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
413
Figure 7-31 Maximum permitted ambient temperature depending on the radiated power
7.12.3.6
Use of the transponder in hazardous areas for dusts
The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are
higher than 210 °C (smoldering temperature). The ignition temperature specified here
according to IEC 60079-0: 2011 for ignition protection type ib in this case references the
smoldering temperature of a layer of combustible flyings (ib IIIA) or alternatively non-
conductive dusts (ib IIIB).
Temperature class grading for dusts
WARNING
Ignitions of dust-air mixtures
When using the RF640T transponder, check that the temperature values are adhered to in
keeping with the requirements of the area of application.
Non-compliance with the permitted temperature ranges while using the transponder can
lead to ignitions of dust-air mixtures.
Temperature class assignment for dusts and a radiated power less than 100 mW ERP
If the radiated power of an antenna radiating into the hazardous area or located in the
hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the
value 100 mW, the temperature class assignment is as follows:
Ambient temperature range
Temperature value
-25
°C ≤ Ta ≤ +85 ℃
T96 °C