Meaning of the LED displays
●
The "PWR" LED indicates the operating state of the device:
–
LED flashes slowly at 1 Hz: Device has power supply and is off or in the process of
being switched off.
–
LED flashes rapidly at 3 Hz: Power-on delay is active.
–
LED on: Device is switched on.
●
The "SF" LED lights up red if an error occurs.
●
"TEMP" LED, see table below:
Temperature
in the
device is
"TEMP" LED
for non-arctic
HMI device
"TEMP" LED
for arctic HMI
device
Comments
Too low
Lit red
1
Lit yellow
Power off the device immediately. The device
cannot be powered back on again
immediately.
Very low
Flashing red,
3 Hz
Flashing
yellow/green,
3 Hz
You are urgently advised to move the device
to warmer surroundings. If the device is
switched on in this condition, the device
temperature will usually rise significantly over
time as a result of the waste heat generated
and become non-critical.
Increasing the display brightness can improve
the situation as this generates more heat.
Low
Flashing red,
0.5 Hz
Flashing
yellow/green,
0.5 Hz
The device temperature is low.
You are advised to move the device to
warmer surroundings. If the device is
switched on in this condition, the device
temperature will usually rise significantly over
time as a result of the waste heat generated
and become non-critical.
Increasing the display brightness can improve
the situation as this generates more heat.
Optimum
Off
Green during
heating
Otherwise Off
For handheld operation, you can generally
assume that no part of the device surface is at
a dangerous temperature and that the device
can therefore be held for at least 10 minutes
without the risk of injury/damage from heat.