Technical specifications
5.3 Electromagnetic compatibility
Comfort Panels INOX, ITC INOX
Compact Operating Instructions, 08/2022, A5E33472156-AP
33
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
Sinusoidal interference
Test values
HF radiation (electromagnetic fields)
according to IEC 61000-4-3
Comfort V1/V1.1 devices:
80% amplitude modulation at 1 kHz
•
to 10 V/m from 80 MHz ... 1 GHz
•
to 10 V/m from 1.4 GHz ... 2 GHz
•
to 1 V/m from 2 GHz ... 2.7 GHz
Comfort V2 devices:
80% amplitude modulation at 1 kHz
•
To 10 V/m in the range 80 MHz to 1 GHz
•
To 3 V/m in the range 1.4 GHz to 6 GHz
HF current feed on cables and cable
shields according to IEC 61000-4-6
Test voltage 10 V with 80% amplitude modulation at 1 KHz
in the 10 KHz to 80 MHz range
Magnetic field intensity
50/60 Hz; 100 A/m RMS
Emission of radio interference
The following table shows the interference emission from electromagnetic fields according to
EN 61000-6-4, measured at the following distance.
Radiated emission (emitted interference)
Frequency range
Measuring distance Interference emission
30 ... 230 MHz
10 m
< 40 dB (
μ
V/m) quasi-peak
230 ... 1000 MHz
10 m
< 47 dB (
μ
V/m) quasi-peak
1 ... 3 GHz
3 m
< 76 dB peak and < 56 dB average
3 ... 6 GHz
3 m
< 80 dB peak and < 60 dB average
Emission of radio interference voltages
Frequency range
Interference emission
0.150 ... 0.5 MHz
< 79 dB quasi-peak and < 66 dB average
0.5 ... 30 MHz
< 73 dB quasi-peak and < 60 dB average
See also