Installation and mounting
5.6 Connecting the charging station
SICHARGE D
Operating Instructions, 02/2021, 8EM5907-0AA00-1AA7.01
71
PE conductor
First connect the protective conductor of the DC cable to the terminal lug on the right:
1.
Select an M10-size cable lug for the corresponding conductor cross-section.
2.
Strip off the end of the conductor so that the remaining insulation reaches up to the cable
lug.
3.
Fasten the cable lug correctly to the end of the conductor.
4.
Secure the protective conductor to the copper bar with an M10 fastening nut and a
tightening torque of 40 Nm.
5.
Mark the drawn connections, for example, with a red paint stick.
Connecting DC+ and DC- conductors
Connect the DC+/DC- conductors of the dispenser cable.
To connect a DC conductor, follow these steps:
1.
If necessary, insulate the cable lug sleeve to maintain the minimum clearances and creepage
distance.
2.
Insert the connection bolt through the screw holes of the cable lug and copper bar.
3.
Tighten the fastening nut with the required torque:
–
Size of fastening nut: M10
–
Required tightening torque: 40 Nm
4.
Mark the drawn connections, for example, with a red paint stick.
Auxiliary power supply
The SICHARGE D charging station can supply the associated dispensers with the required
230 V operating voltage via a secure auxiliary power supply.