BA 9142 en 02/2015
13
10
12
11
7
2
1
3
4
5
9
8
6
Fig. 9:
Gear unit features for preservation measures
1
Ventilation sealing cap
2
Oil drain sealing cap
3
Sealing cap
4
Air filter (gear unit)
5
Oil level indicator (gear unit)
6
Suction line (gear unit)
7
Oil drain (gear unit)
8
Pressure line (gear unit)
9
Pressure line (tilting pad thrust bearing
chamber)
10
Oil drain (tilting pad thrust bearing
chamber)
11
Air filter (tilting pad thrust bearing
chamber)
12
Oil level indicator (tilting pad thrust
bearing chamber)
13
Round cord hollow profile
•
Replace the air filter of the tilting pad thrust bearing chamber (11) with a screw plug
(at start-up, the screw plug must be replaced for the air filter again).
•
The lower oil drain cock on the gear unit (7) must be provided and sealed with a screw plug.
•
If not already done beforehand, close ventilation of the sealing cap (1).
NOTICE
Property damage
Corrosion is possible when the gear unit is opened for too long.
Close the gear unit airtight again, at the latest one hour after complete filling.
Note
Before restarting the gear unit, the measures according to section 7.1 and 7.2 have to be carried out.
7.3.2
Exterior corrosion prevention
•
Clean the surfaces.
•
Apply preservative agent.
Note