Configuration
4.9 Security
CP 1243-1
68
Operating Instructions, 04/2017, C79000-G8976-C365-03
4.9.4.2
Notation for the source IP address (advanced firewall mode)
If you specify an address range for the source IP address in the advanced firewall settings of
the CP, make sure that the notation is correct:
●
Separate the two IP addresses only using a hyphen.
Correct: 192.168.10.0-192.168.10.255
●
Do not enter any other characters between the two IP addresses.
Incorrect: 192.168.10.0 - 192.168.10.255
If you enter the range incorrectly, the firewall rule will not be used.
4.9.4.3
Firewall settings for configured connection connections via a VPN tunnel
IP rules in advanced firewall mode
If you set up configured connection connections with a VPN tunnel between the CP and a
communications partner, you will need to adapt the local firewall settings of the CP:
In advanced firewall mode ("Security > Firewall > IP rules") select the action "Allow*" for both
communications directions of the VPN tunnel.
See also
Settings for online security diagnostics and downloading to station with the firewall activated
(Page 68)
4.9.4.4
Settings for online security diagnostics and downloading to station with the firewall
activated
Setting the firewall for online functions
With the security functions enabled, follow the steps outlined below:
1.
In the global security settings (see project tree), select the entry "Firewall > Services >
Define services for IP rules".
2.
Select the "ICMP" tab.
3.
Insert a new entry of the type "Echo Reply" and another of the type "Echo Request".
4.
Now select the CP in the S7 station.
5.
Enable the advanced firewall mode in the local security settings of the CP in the "Security
> Firewall" parameter group.
6.
Open the "IP rules" parameter group.