DIAGNOSTIC TERMINAL (DT) SOFTWARE
_________________________________________________________________________________________________________
6-15
SIG-00-07-11 SEPTEMBER 2012 (REVISED OCTOBER 2019)
Version No.: B.2
6.7.3 PHYSICAL Configuration
NOTE
Siemens recommends that users program the PHYSICAL
configuration parameters prior to programming the LOGICAL
configuration parameters. In many cases, the changes to the
PHYSICAL configuration menus executes a Set to Default action,
and any LOGICAL configuration settings are reset to their default
settings.
Select the
PHYSICAL Configuration
function
from the MAIN PROGRAM menu screen to view
the PHYSICAL configuration screen (Figure 6-19).
A list of physical configuration options is displayed
Figure 6-19 PHYSICAL Configuration Screen
6.7.3.1
Physical Layout
Each Physical Layout file describes the physical content of the associated object. For instance,
the Mainbox is the main VIU.
The Physical Layout file for this object defines the types of circuits installed in the main VIU.
Click the MainBox (green text) to select a different template (i.e., MainBox8:MainBox8,
Remote1:Remote1, etc.). The contents of these files are defined in the MCF.